@melicherm
Copy link

Hello dear community, with the aspect of security, is there the possibility to allow only read operations through the gateway?

or could this feature be added with a context switch -ro ?

One could modify the code and build the app without write features, but this could be interesting.... to have a hardened security feature.

Thanks!

@mStirner
Copy link

How should that work?
To read a modbus register/value, you have to write on the Bus.

The only "read only" modus i can image is a simple monitoring of the messages on the Bus/USB Adapter.

Can you elaborate more what you expect?

@melicherm
Copy link
Author

melicherm commented Nov 28, 2024

Hello,
good point.

The use case:

We have a network of around 20 frequency controllers behind an Modbus RTU to Modbus IP gateway running mbusd. We use Zabbix to monitor the values over the gateway with the use of ,,modbus_read" function. Obwiously it's a separated dedicated network, but still...

example:
modbus_read[{HOST.CONN}:{$MODBUS_PORT},{$MODBUS_SLAVE},1,4,uint16]

modbus_read[192.168.1.10:502,20,1,4,uint16]

But we are hardening our security and we would like to reject "write" commands coming to the IP side. So no Write command could be directed to RTU side from IP side. Hope i have explained it clearly -> the use case.

Buf if there would be a function modbus_write[] this could bring security issues -> someone could turn ON or OFF devices, etc... we have seen such articles in the news :)

@melicherm
Copy link
Author

@mStirner - Any thoughts on this? How to mitigate possible write command coming over IP to mbusd?

@mStirner
Copy link

mStirner commented Dec 10, 2024

afaik there is no build in method.
There are two possible solutions.

  1. Restrict the access to mbusd via firewall rules
  2. write a custom gateway that checks the modbus function code

The second solution could be done in python or node, just a few lines of code:

const { createConnection, Server } = require("net");

const server = new Server();

server.on("connection", (socket) => {

    let connected = false;

    // listen for incoming data once (from zabixx)
    // if function code is valid, the client & mbusd streams are piped below
    socket.once("data", (chunk) => {

        // not sure which byte is function code in a Modbus IP packet
        // chat gpt said byte 8
        // example: 00 01 00 00 00 06 01 03 00 00 00 02
        /*
        - Transaction ID: 00 01 (2 Bytes)
        - Protocol ID: 00 00 (2 Bytes)
        - Length: 00 06 (6 Bytes folgen)
        - Unit Identifier: 01 (1 Byte)
        - Function Code: 03 (Read Holding Registers)
        - Data: 00 00 00 02 (Startadresse 0x0000, 2 Register read)
        */

        // check if byte 8 is either 1, 2 or 3
        // and connect to mbusd + forward data
        // TODO: not sure if need to hex formated (0x01) or plain int
        if ([1, 2, 3].includes(chunk[7])) {
            if (!connected) {

                // connect to mbusd
                // IMPPORTANT: configure mbusd to listen only on the loopback interface!!!!
                let client = createConnection(502, "127.0.0.1", () => {
                    connected = true;
                });

                client.pipe(socket); // pipe data from mbusd to client
                socket.pipe(client); // pipe data from client to mbusd

                client.write(chunk); // write initial message chunk to mbusd

            }
        } else {

            // wrong modbus function code
            // drop connection
            socket.end();

        }

    });

});

// "expose" our gateway instead of mbusd to the network
// mbusd should only listen on the loopback interface
server.listen(502, "192.168.1.123", (err) => {
    console.log(err || "Modbus gateway listening on tcp://192.168.1.123:502");
});

Not tested, just put quickly together.
The code above is not perfect, it missing error handling, and im not sure if the stream pipeing is even needed because of the low size of modbus messages, this could be even done with a single "data"/"chunk" event, which should make the code above even smaller/simpler.