Notifications
You must be signed in to change notification settings - Fork 27
/
x10sched.5
674 lines (590 loc) · 27.8 KB
/
x10sched.5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
.TH X10SCHED 5 local
.SH NAME
.B x10sched\^
- layout of the x10.sched file for the X-10 CM11A serial interface
.SH DESCRIPTION
.I heyu
supports uploading a schedule of events to your CM11A interface.
The schedule file (by default named "x10.sched") allows you to specify
when you want X10 commands to be sent to X10 modules throughout your home.
It also allows you to translate some X10 codes to other codes. More on that below.
.PP
The X-10 CM11A connects to a computer with an RS232 interface.
It can store about 128 events; each event can do things like turn on,
turn off, or dim up to sixteen X10 modules. The CM11A box has a
battery backed clock which the computer can read. The event data is
stored in EEPROM memory. After a schedule is uploaded, the CM11A can
be disconnected from the computer and even plugged in elsewhere in the
house if desired.
.PP
There are three important concepts used in the x10sched file. They are timers,
triggers and macros. They all work together, in fact, the timers and triggers
execute macros.
.PP
The TIMER determines the date and time that a macro will be executed.
Once a minute the CM11A looks at its internal table (frequently referred
to as the EEPROM) to see if it\'s time to do anything. Timers can be
restricted to certain days of the week or ranges of dates, or both.
.PP
The TRIGGER represents real time actions. When the CM11A sees a powerline
signal it compares the command with its table of triggers (also known as
"macro initiators") and executes the appropriate macro. Triggers can be used
to cause many actions when one remote control button is pushed.
.PP
The MACRO consists of a label, an optional delay and a list of commands.
Each macro can have up to 255 commands. The delay can be from 0 to
240 minutes. Macro labels can be significant. They can remind you of
what it is supposed to do or it can remind you what triggers it. The label
turn_c5_on_now leaves nothing to be imagined.
.PP
There is no command that will dump the contents of the CM11A EEPROM to the serial port.
This makes it impossible to alter discrete events or macros unless the entire
table is known. This means that we can\'t set the macros using another
program (ActiveHome(TM), for instance) and then add a new macro from Heyu.
.PP
The timers and macros are stored in a file, by default in the same directory
as the configuration file x10config. (See x10config(5)). The default file name
for the schedule file is x10.sched. You can override the defaults by
specifying the filename in the configuration file "x10config" with
the SCHEDULE_FILE directive. (It must be stored in the same directory
as the configuration file.) You can also override the defaults by
providing a fully qualified pathname in the environment variable X10SCHED
or with the "-s" command line switch.
.PP
The macro upload function will not work without a schedule file.
.PP
Comments and blank lines are allowed in the file to make it more readable.
White space is normally ignored.
.PP
.SH FILE FORMAT
Refer to the sample file (x10.sched.sample) that came with the source
code to help in understanding this section.
.PP
There is no prescribed order for timer, trigger, macro, and comment
lines in the schedule file - they may be grouped by type or mixed,
at the user\'s option.
.PP
The following are case-sensitive: X10 commands; macro labels;
labels for aliases, scenes, and usersyns as defined in the config file.
.br
Housecode letters are not case-sensitive, nor is the day-of-week mask
or any of the keywords used in the schedule file, e.g. TIMER, timer,
tiMer are all equivalent.
.PP
.IP \fBcomment\fP
As of version 2.0, anything on a line following a pound sign (#) is
treated as a comment and is ignored by Heyu. Note that for versions of
Heyu earlier than 2.0, a pound sign anywhere other than as the first
character on a line was treated as a normal character and NOT treated
as beginning a comment.
.PP
.IP \fBsection\fP
Any line beginning with the keyword \fBsection\fR is totally ignored
by Heyu, just as if it were a comment line. It is provided to enable
user-defined breakpoints for external programs or scripts which might
be devised by the user to reorganize a schedule file, and where use
of ordinary comment lines for this purpose might be confusing.
.PP
.IP \fBblank lines\fP
Blank lines are skipped over.
.PP
.IP \fBtimer\fP
The timer line consists of 7 required items. They are: the literal string
\fBtimer\fR (which is not case-sensitive), a day of week mask, the begin
and end date range, the start time, the stop time,
the start macro and the stop macro. In addition to these, there are
several timer options which can be appended to the line.
.RS 7
.br
The \fIday of week mask\fR (DOW) is a 7 character field. Each position
represents a day of the week when the timer should work. A timer
that should execute every day is represented by the string "smtwtfs".
To deactivate a timer for any chosen day of the week, substitute a period
\'.\' for the appropriate letter.
.br
For instance, to activate a timer for Monday, Thursday and Saturday, you\'d
use the following string: ".m..t.s" (without the quotes).
.br
The DOW mask is combined with the date when the CM11A checks to see
if it should execute a timer. Both date and DOW must match for the timer
to execute.
.PP
The \fIbegin-end range\fR is a pair of month and day dates separated by
a hyphen \'-\' or by a colon \':\'. The first date represents when to begin,
and the second represents when to end. The range is inclusive.
.PP
The order in which month and day appear in each date must agree with the
order specified with config directive DATE_FORMAT (or its default),
for example with the default \'DATE_FORMAT YMD\', the date range would be
entered as mm/dd-mm/dd, whereas for \'DATE_FORMAT DMY\' it would be entered
as dd/mm-dd/mm. The separator between month and day may any of the
separators which can optionally be specified with DATE_FORMAT, namely
\'/\', \'-\', or \'.\'. It does not have to be the same one.
.PP
A single date can be specified by using the same values for the
begin and end dates. Older versions of Heyu required that the begin date
be less than or equal to the end date. Beginning with version 2.0, Heyu
will interpret a begin date later than the end date as meaning the
date range wraps around at the end of the year into the beginning of the year
(including the current year).
.br
Examples:
.br
You would use 01/01-12/31 to indicate a timer that should be run daily.
.br
The range 12/01-02/01 is equivalent to the two ranges 12/01-12/31 and
01/01-02/01
.br
With DATE_FORMAT DMY, the above range could be specified as 01-12:01-02,
01.12-01.02, or 01/12-01/02
For a date range involving the last day of February, see the description of the
\fIFEB_KLUGE\fR directive in x10config(5).
.br
Beginning with Heyu version 2.0, the effective date range of an uploaded
schedule can be configured to span years. A schedule uploaded at any
time during the year can be configured to operate correctly for a period
of from 1 to 366 days beginning on the upload date. So for example, a schedule
uploaded on September 1st can be configured to run correctly and continually
through September 1st (or 2nd) of the following year. For more information,
see the descriptions for the \fIMODE\fR and \fIPROGRAM_DAYS\fR directives
in the x10config(5) man file, in particular "HEYU" mode versus "COMPATIBLE"
mode.
.br
Regardless of the above directives, the user would normally program the
schedule for the entire year. (Envision the schedule as being repeated for
each year, past, present, and future.) When compiling for upload, Heyu
automatically selects whatever parts of it are to be used in accordance with
those directives and adjusts dates and times for Leap Years and Daylight
Saving Time as required.
.br
As a special case beginning with Heyu 2.0, the date range "mm/dd-mm/dd"
may optionally be entirely replaced with the expression "expire-dd", where dd
represents the range of dd+1 days ending on the last day of validity of
the uploaded schedule. Thus the CM11A can be programmed to execute some
macro as a reminder to the user that the schedule will shortly need to be
reloaded. Note that in COMPATIBLE mode, reloading the schedule
before Jan 1st will not accomplish anything, as the exact same schedule
will be loaded.
.br
The \fIstart\fR and \fIstop\fR times are in hh:mm format
(hour:minutes 24 hour clock) You don\'t have to use two digits, 1:5 will
work just fine for 5 minutes after 1 AM.
.br
The \fIstart macro\fR and \fIstop macro\fR will be executed when their
respective time is reached. Note that these are really unrelated and
independant timers, and that the start macro is not restricted to turning
things on and that the stop macro does not have to control the same X10
modules as the start macro. Either the start or stop macro can be the
macro named "null" which is a dummy macro - it\'s never executed and thus
does nothing.
.br
The macros referenced in the timer must be defined somewhere in the file.
The schedule upload will abort if a macro is missing or mis-typed. (A warning
will be issued if a macro is not referenced by any timer or trigger.)
.br
With versions of Heyu prior to 2.0, times for events had to be programmed
separately for dates when Standard Time and Daylight Time were in effect.
Beginning with version 2.0, the user programs times for all events in
legal (i.e., wall clock) time, and Heyu makes the necessary internal
adjustment for the changeovers from Daylight -> Standard and vice-versa.
The CM11A clock is maintained on Standard Time year around, transparent
to the user.
.br
Also new with version 2.0 is the ability to directly specify times
relative to Dawn and Dusk. (A separate program was supplied with earlier
versions to do this.) Instead of the time expressed as "hh:mm", one can
now use the format "dawn+mm" or "dawn-mm" or "dusk+mm" or "dusk-mm"
(or just "dawn" or "dusk"). Heyu calculates the times of Dawn and/or Dusk
and makes the substitution. The "mm" represents the number of minutes
before or after Dawn/Dusk when the macro will be executed. "mm" can have
any value, _except_ that the resulting time after resolving the times of
Dawn/Dusk must fall within the range 00:00 to 23:59 or Heyu will quit
with an error message.
.br
Dawn and Dusk are defined by default to be synonymous with sunrise and
sunset. However this definition may be _globally_ changed to one or
another of the standard twilight times, or to a user specified Sun position,
with the configuration file directive DAWNDUSK_DEF. See man page x10config(5).
.br
When Heyu processes Dawn or Dusk related events, it subdivides the
programmed date range into a number of unequal-length subintervals,
each of which is assigned a constant time approximating the time
of Dawn or Dusk over the subinterval. The number and lengths of these
subintervals are chosen by an iterative procedure which minimizes the
deviation from actual Dawn/Dusk times subject to the constraint of
available EEPROM memory in the CM11A. (As a result, if Dawn and/or
Dusk related event times are programmed, the amount of free EEPROM
memory displayed will generally be pretty small. If more timers
are added to the schedule they'll fit - within limits of course -
but the deviation in the Dawn/Dusk times will be higher.)
.br
The Dawn or Dusk "error" reported by Heyu is the difference in minutes
between the maximum and minimum times of daily Dawn or Dusk over
the above-mentioned subinterval. Whether this error in the constant time
approximation on any particular day is plus or minus or mixed is determined
by the DAWN_OPTION or DUSK_OPTION configuration directive.
.br
Heyu requires that every day have a Dawn and a Dusk, which is not
the case in polar latitudes when the sun may be above or below the
horizon all day, or when Dawn or Dusk is shifted into the previous
or following day.
.br
To compensate, Heyu uses a ficticious Dawn and/or Dusk
at 00:01 or 23:58 hours Standard Time (not necessarily repectively)
as the situation dictates. So for example in polar mid-summer, Heyu
will represent the day as occurring between 00:01 and 23:58, while
in polar mid-winter, the night will be considered to occur between
those times.
.br
To activate the so-called "security" feature of the CM11A, simply append
the letter \'S\' to the programmed start or stop time in question. "12:00s",
"dawn+5s", "duskS" are valid examples of this. The time of the event
will then vary each day by some random amount within +/- 30 minutes
of the programmed time. Note that the CM11A itself actually applies
a variation of between +0 and +60 minutes to the programmed time. Heyu
subtracts 30 minutes from the programmed event time to get the +/- 30 minute
variation.
.PP
Heyu has to use a few tricks with the security feature when clock times around
midnight are programmed, in particular when the programmed time is
between 22:59 and 01:30 (assuming Daylight Time is in effect at some
time during the year in your locality), since the CM11A must be allowed
to add a random time between 0 and 60 minutes at any time of the year
without exceeding 23:59. To get around this, Heyu changes the programmed
event time for the timer to 22:59 and creates an appropriately delayed macro.
.br
But this solution has its own problem, namely that if a delayed macro does
not execute until the following day, it will not be executed at all on the
day the schedule is uploaded. To get around this, Heyu uses a non-delayed
macro and creates a new one-day-only timer event with its own +/- 30 minute
randomly generated variation around the user\'s original programmed time.
.br
In order to test the operation of a schedule without having to wait
around all day, Heyu version 2.0 will acccept the construct "now" or
"now+NN" (with NN in minutes) in place of a start time and/or stop time
in a timer. It will then substitute the current system time rounded up
to the next whole minute, with a minimum of 15 seconds allowed for
uploading the schedule. NN must be >= zero, otherwise the only restriction
is that the resolved value of "now+NN" must not exceed 23:59. The security
feature may not be used with the "now+NN" construct. Note that the
date range and DOW mask must include today if the macro is actually
expected to be executed today. Example:
.br
timer smtwtfs 01/01-12/31 now now+2 lights_on lights_off
.br
Beginning with Heyu version 2.0, the reserved macro label "null" may be
used as a "do-nothing" place holder in a timer, when neither of the
timer concepts \fIstart\fR or \fIstop\fR seem logically appropriate. (The null macro
may be used liberally as required - it will take up no more space in the
CM11A\'s EEPROM memory than if the user manually rearranged timer start
and stop events solely to have something to "fill in the blank".)
.br
\fItimer options\fR
.br
There are four timer options which can be used to restrict the execution of
a timer only to days when the actual times of Dawn or Dusk during the year are
less than (LT) or greater than (GT) the time specified with the option.
The option keyword and time are appended to the end of the normal timer line.
.br
DAWNLT hh:mm - Execute only on days when Dawn occurs before hh:mm
.br
DAWNGT hh:mm - Execute only on days when Dawn occurs after hh:mm
.br
DUSKLT hh:mm - Execute only on days when Dusk occurs before hh:mm
.br
DUSKGT hh:mm - Execute only on days when Dusk occurs after hh:mm
.br
where hh:mm is expressed as legal (i.e. wall-clock) time.
Example:
.br
timer smtwtfs 01/01-12/31 dusk 21:00 light_on light_off DUSKLT 21:00
.br
This would result in the light being turned ON at dusk, OFF at 9:00 PM,
but only on days when Dusk occurs earlier than 9:00 PM. Thus in extreme
latitudes when Dusk might occur later than 9:00 PM during the summer
months, the situation is avoided where the light is turned ON at Dusk and
remains ON all night and all the next day until 9:00 PM.
.br
The timer options are not restricted to timers which involve Dawn or Dusk
times. The above timer could just as well have been programmed as two
separate timers:
.br
timer smtwtfs 01/01-12/31 dusk 00:00 light_on null DUSKLT 21:00
.br
timer smtwtfs 01/01-12/31 21:00 00:00 light_off null DUSKLT 21:00
.br
The time argument for the option does not have to be the same as the
execution time of the timer. In the above example it might seems silly
to have the light come ON for only a few minutes on days when Dusk
started to approach 9:00 PM, so one could use DUSKLT 20:50 to
ignore the days when the light might otherwise be ON for less than
10 minutes.
.br
More than one timer option can be used with a timer - all four in fact
if deemed appropriate. Just string them together at the end of the
timer line. The string ... DUSKGT 19:00 DUSKLT 21:00 would result
in the timer being restricted to execute only on days when Dusk occurs
between 7:00 PM and 9:00 PM.
.br
Please note that the CM11A interface has no capability for conditional
logic - Heyu merely compares the option time argument with the calculated
Dawn or Dusk time for each day of the year and breaks up the date interval
into multiple intervals.
.br
.RE
.IP \fBtrigger\fP
The trigger line consists of only 4 items. They are: the literal string
\fBtrigger\fR, the trigger unit, the command and the macro.
.RS 7
.br
The \fItrigger unit\fR is a combination of house code (a letter from a-p) and
a unit number (from 1 to 16). An example is d12.
.br
The \fIcommand\fR will be either the word on or the word off. The CM11A will
not trigger on any other type of X10 signal.
.br
The \fImacro\fR refers to a macro that will be executed. The macro must be
defined somewhere in the file.
.RE
.IP \fBmacro\fP
.RS 7
.br
The \fImacro\fR line consists of 3 or 4 items. They are: the literal
string \fBmacro\fR, the label, an optional delay, and a semicolon-separated
list of one or more commands or scenes.
.br
The \fIlabel\fR is plain text of up to 32 characters which must be
contiguous, and must be of printable characters. It must not begin with
the characters \'+\', \'-\' or \'_\', and it must not contain the \'$\'
character. The label is used by the timers and triggers to find the
correct macro.
.br
When Heyu uploads a schedule, it write the macro names and EEPROM memory
locations in file "x10macroxref" in the Heyu base directory, i.e., the
directory where the configuration file is located. This file is used
by the Heyu monitor to translate macro memory location to readable
macro names as they are executed, so should not be deleted.
.br
The \fIdelay\fR can be from 0 to 240 minutes long. It is represented by a
simple cardinal number; no fractions, signs or decimals. However see
the section "Problems with delayed macros" below.
.br
The \fICommands\fR can be of several types; on, off, dim or bright
being the most commonly used. The on and off commands have one argument,
that being the address of the modules to be controlled. The address
can be in the format of house code (hc) followed immediately by the unit
number or range of unit numbers. The following are valid: d1 d1,2,3,9 d1-4,6
.br
.RE
.IP \fBconfig\fP
.RS 7
A limited subset of configuration directives
may appear in the schedule file when preceded by the word \'config\', and will
override the values of those same directives in the configuration file (or
their default values). This feature is intended for use if you upload
schedules requiring different configurations on a frequent basis, so you don\'t
have to keep changing the configuration file every time. For most users
however there\'s less chance of confusion by relying only on the
directives as specified in the configuration file.
.PP
The subset of directives includes only those which directly influence how
Heyu processes the timers, triggers, and macros to create the uploaded EEPROM
image, to wit: MODE, PROGRAM_DAYS, LATITUDE, LONGITUDE, COMBINE_EVENTS,
COMPRESS_MACROS, DAWNDUSK_DEF, DAWN_OPTION, DUSK_OPTION, MIN_DAWN, MAX_DAWN,
MIN_DUSK, MAX_DUSK, ASIF_DATE, ASIF_TIME, DATE_FORMAT,
WRITE_CHECK_FILES, REPL_DELAYED_MACROS, FEB_KLUGE, RESOLVE_OVERLAP.
See x10config(5) if necessary for an explanation of these directives.
Heyu will quit with an error message if directives other than these are
specified in the schedule file.
.PP
Configuration directive lines in the schedule file always apply to the
schedule as a whole regardless of where they appear in the file. It\'s
good practise however to put them all at the beginning of the
file so you won\'t overlook them later on and get confused.
.PP
Example:
.br
config program_days 90
.SH COMMANDS
.PP
In addition to the on, off, dim, and bright commands, Heyu version 2
adds others which can be used for uploadable macros in schedules,
including Extended commands for modules like the X-10 LM14A 2-way lamp
module.
Run \'heyu help\' for a complete list of commands implemented in the
current version of Heyu. All the native X10 commands _except_ the
Preset command may be used for uploaded macros. (The command \'mpreset\'
implements the very limited support for Preset in uploaded macros
provided by the CM11A firmware.)
.PP
Heyu version 2 includes built-in synonyms for many of the commonly used
commands. Run \'heyu syn\' to see these synonyms.
.PP
Heyu version 2 also includes the ability for users to define their
own synonyms ("usersyns") and/or compound commands ("scenes") in
the configuration file, and use them in macros.
.PP
X10 commands are generally transmitted over the power line in two
"chunks", a series of address bytes, one for each unit, followed by
one or more function bytes. Both the address byte and the function
byte reference the housecode (except for the \'preset\' command, which
has a peculiar function byte format).
.br
For some commands, the unit information contained in the address byte
is superfluous and the address byte will normally be omitted. Examples
of commands in this category include the "all" commands like \'lightson\',
and \'alloff\', the \'hail\' command, and any of the Extended commands (which
include the unit code within the function structure).
.br
No unit codes need be appended to the housecode for the "all" commands, e.g.,
.br
lightson A
alloff C
.br
are sufficient. If a unit is specified with the housecode, it will normally
be ignored. However if for some reason it is desireable for the command to
be issued along with an address byte, prefix the housecode with a \'+\' sign
and add the unit string suffix, e.g.,
lightson +A4
.br
An address byte is not normally sent with the Extended Code commands like
\'xpreset\' even though the unit must be specified. But again, prefixing
the Housecode|Units with a \'+\' sign will instruct Heyu to include an
address byte in the transmission.
.br
For the opposite effect, i.e. to suppress transmission of the address byte
for any command, prefix the Housecode|Units with a \'-\' sign and omit the
units. E.g.,
.br
on -A
.PP
A few commands warrant additional description:
.br
xfunc <T/F> HU <xx> - general extended command.
.br
The \'xfunc\' command will transmit any arbitrary extended function <T/F>
and data byte <xx>, where both are assumed to be hexadecimal bytes (0-0xff).
.br
Example: 0x31 is the function code for the extended preset command, and the
following commands for setting the extended preset level for module
c3 to level 26 (decimal) are equivalent:
.br
xpreset c3 26
xfunc 31 c3 1a
.br
The extended command code functions are described in X-10\'s document
xtdcode.pdf (a replacement for the older XTC798.DOC) which is available
for download from their website. The only extended code Types known to
be applicable to existing modules are the Type 3 for extended code lighting
and appliance modules and Type 0 for the Marmitek SW10 Shutter controller.
.PP
Macro commands can be strung together by separating them with a semicolon \';\'.
This allows one macro to affect several devices. Consider the commands needed
to turn on the TV (d1) turn off the stereo (d3) and dim the 4 lights in the
living room by half( c1, c2, c3 and c4 dim 11). This macro command string would
do it.
.br
on d1; off d3; dim c1-4 11.
.br
As of Heyu version 2, macros can include scenes defined in the user\'s
configuration file as if they were standard Heyu commands. Macros can
also reference aliases defined in the configuration file in place of
the Housecode|Units parameter.
.PP
.RE
.SH EXAMPLES
.PP
In this timer, the macro c5on will be executed once a day at 2:58 PM. The
macro c5off will execute at 2:59 PM.
.br
The timer is active every day of the week from 2/1 through 12/12.
.br
timer smtwtfs 02/01-12/12 14:58 14:59 c5on c5off
.br
The next one only runs on Dec 11, and then only if it falls on a Friday.
.br
timer .....f. 12/11-12/11 23:34 23:35 d6off d6off
.br
This timer sounds a chime (perhaps a Universal Module UM-506) every day
at Noon, legal (wall clock) time, Monday through Friday, regardless of
whether Standard or Daylight Time is in effect (Heyu ver 2.0 and later):
.br
timer .mtwtf. 01/01-12/31 12:00 00:00 lunch_chime null
.br
This one sounds a chime at 7 AM and 7 PM 3 days in a row before
the expiration date and on the final date itself (a total of 4 days)
to remind the user that the uploaded schedule will shortly become
invalid and need to be reloaded. (Heyu ver 2.0 and later only):
.br
timer smtwtfs expire-3 07:00 19:00 chime chime
.br
The following two timers turn on an inside hall light 30 minutes before
Dusk, dim it after 11 PM, and turn it off 15 minutes after Dawn (Heyu ver
2.0 and later):
.br
timer smtwtfs 01/01-12/31 dusk-30 23:00 hall_on hall_dim
.br
timer smtwtfs 01/01-12/31 dawn+15 00:00 hall_off null
.br
The following timer operates decorative lighting between Dusk and 10 PM
during the holiday season without quitting on Jan 1st during non-leap
years (Heyu version 2.0 and later):
.br
timer smtwtfs 12/15-01/02 dusk 22:00 xmas_on xmas_off
.br
This trigger runs macro c5off when \'c1 off\' is received.
The net effect would be that the device with the code c1 will be turned off AND
whatever the macro c5off directs will be done too.
.br
trigger c1 off c5off
.br
In the following, E4 is a dusk sensor (MS13A) outside. It turns on the
living room lamps (via the livinroom_on macro), but it does not turn them off.
I use a timer to do that long before midnight. If I waited for the MS13A
they\'d turn off at dawn even if I\'m reading my paper then.
.br
trigger E4 on livinroom_on
.br
This next macro is labeled c5off. It waits 5 minutes, then turns off
d6 and d7 and turns on e2
.br
macro c5off 5 off d6,7; on e2
.br
And this macro includes dimming.
.br
macro c5on 0 on d7; dim d7 8
.br
Since the delay is optional, the above can also be written as:
.br
macro c5on on d7; dim d7 8
.SH Multiple Transmissions
If the Multiple Transmissions box is checked for a timer in X10\'s
ActiveHome software, the timer is duplicated with the same macros but
with the execution time set 1 minute later. This is simple enough
to do manually (and with more flexibility) in the schedule file that
no attempt has been made to automate this feature in Heyu.
.SH Problems with delayed macros.
If a new schedule is uploaded between the time a timer or trigger
is activated and the time a delayed macro is executed, the macro
will never be executed because pending delayed macros are purged
when a schedule is loaded. This is the nature of the hardware
and is unavoidable. It should never be necessary for the user
to program a delayed macro for a timer, and if Heyu finds one it
by default attempts to adjust to this situation by creating a non-delayed
macro and increasing the time of the timer to compensate. To change
Heyu\'s behavior, see the REPL_DELAYED_MACROS directive in x10config(5).
(If the same macro is associated with a trigger, the original delayed
macro is uploaded for the trigger in addition to the new macro
for the timer.)
.br
.SH ENVIRONMENT
.br
X10SCHED - Points to a fully qualified file name of your schedule file (timers, and macros).
.SH AUTHORS
Daniel B. Suthers ([email protected])
Charles W. Sullivan ([email protected])
.SH SEE ALSO
.br
http://www.heyu.org
.br
date(1), x10config(5), heyu(1), x10.sched.sample