I find several problems during ED simulation.

Bug 1: Diffraction intensity is not normalized to 1, when incident illumination is tilted, i.e. when input_multislice.theta!=0.

Bug 2: When input_multislice.theta!=0, the position of central electron beam without diffraction is wrong, which should move in the opposite direction. This is a minor difference that is hard to notice, because the diffraction pattern is right but the movement direction of central beam is inconsistent with the intensity changes of diffraction peaks.