Hi, I've noticed a couple of weird names for the register macros.
For instance TMC2300_EN_SPREADCYCLE_SHIFT_FIELD should likely have been named TMC2300_EN_SPREADCYCLE_FIELD.
StallGuard result register field macro is named TMC2300_SG_VALUE here and in the table in section 5.3 StallGuard Control in the documentation on page 25, except it says SG_RESULT in the respective description.
Hi, I've noticed a couple of weird names for the register macros.
For instance
TMC2300_EN_SPREADCYCLE_SHIFT_FIELD
should likely have been namedTMC2300_EN_SPREADCYCLE_FIELD
.StallGuard result register field macro is named
TMC2300_SG_VALUE
here and in the table in section 5.3 StallGuard Control in the documentation on page 25, except it saysSG_RESULT
in the respective description.https://www.analog.com/media/en/technical-documentation/data-sheets/TMC2300_datasheet_rev1.09.pdf#page=25
The text was updated successfully, but these errors were encountered: