Case Name | Case Desciption | Base Model | Test Type |
Results Match |
Comments |
---|---|---|---|---|---|
SPE10-MOD01-01 | Three-Phase, with Cartesian regular grid. | MODEL-01 | Yes | Results are comparable to other vendors as presented in the paper. however, E100 fails to run to completion. | |
SPE10-MOD01-02 | Two-Phase, with Cartesian regular grid. | MODEL-01 | Int | Yes | Results are comparable to other vendors as presented in the paper; however, E100 fails to run to completion. |
SPE10-MOD01-03 | Three-Phase, with Corner-Point regular grid. | MODEL-01 | Yes | Results are comparable to other vendors as presented in the paper. E100 not tested. | |
SPE10-MOD01-04 | Two-Phase, with Corner-Point regular grid. | MODEL-01 | Yes | Results are comparable to other vendors as presented in the paper. E100 not tested. | |
SPE10-MOD02-01 | Three-Phase, with Cartesian regular grid. | MODEL-02 | Yes | Results are comparable to other vendors as presented in the paper. E100 not tested. | |
SPE10-MOD02-02 | Two-Phase, with Cartesian regular grid. | MODEL-02 | Int | Yes | Results are comparable to other vendors as presented in the paper. E100 not tested. |
Both models are based on the SPE 10 comparative SPE paper:
"Tenth SPE comparative solution project: a comparison of upscaling techniques" By Mike Christie (Heriot-Watt University) and Martin Blunt (Imperial College) SPE, August 2001.
Originally, these tests were derived when OPM Flow was only able to run three-phase models, and thus these tests were formulated as pseudo two-phase cases. For 2022, the tests have been re-factored with corrections, and OPM Flow results have been compared with the published results. Both two-phase and three-phase OPM Flow cases give exactly the same results, and the results are comparable to the published results from various vendors.
Notes:
- Test Type column shows if the case is used for intergration testing (Int), or regression teststing (Reg)
- Results Match column indicate if the OPM Flow results match the published results, see the SPE10.odp document for comparisons.
- Model one cases run with ten day time steps for comparison purposes.
- Model two used variable time steps and requires CPR to run, see the parameter files.
Version: 04 January 2023
SPE 10 - MODEL 1 intial ternary saturation plot.
and final ternary saturation plot.
OPM Flow results compared with published results.
OPM Flow results are comparable to the results of other vendors presented in the paper. All four OPM Flow cases give exactly the same results.
SPE 10 - MODEL 2 porosity
Permeability
Final ternary saturation
and final pressure distribution.
Two-phase and three-phase results are identical:
OPM Flow results compared with published results, oil production:
Good agreement with published results, although the initial rate seems too high, this seems a common issue at the start of runs, with OPM Flow.
And average reservoir pressure:
Good agreement with published results, although the pressure is a bit on the high side, could probably correct for this by checking the datum pressure etc. Resulted accepted for now.
OPM Flow results are comparable to the results of other vendors presented in the paper.
Both two-phase and three-phase OPM Flow cases give exactly the same results.