Skip to content

Latest commit

 

History

History
161 lines (125 loc) · 7.46 KB

07502L.md

File metadata and controls

161 lines (125 loc) · 7.46 KB
title description addedAt pageClass
Immax 07502L control via MQTT
Integrate your Immax 07502L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2021-11-30 12:10:17 -0800
device-page

Immax 07502L

Model 07502L
Vendor Immax
Description 4 in 1 multi sensor
Exposes occupancy, tamper, battery, illuminance, illuminance_lux, temperature, humidity, reporting_time, temperature_calibration, humidity_calibration, illuminance_calibration, pir_enable, led_enable, reporting_enable, sensitivity, keep_time, linkquality
Picture Immax 07502L

Options

How to use device type specific configuration

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It's not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Tamper (binary)

Indicates whether the device is tampered. Value can be found in the published state on the tamper property. It's not possible to read (/get) or write (/set) this value. If value equals true tamper is ON, if false OFF.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported.. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value.

Illuminance (lux) (numeric)

Measured illuminance in lux. Value can be found in the published state on the illuminance_lux property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Reporting time (numeric)

Reporting interval in minutes. Value can be found in the published state on the reporting_time property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"reporting_time": NEW_VALUE}. The minimal value is 0 and the maximum value is 1440.

Temperature calibration (numeric)

Temperature calibration. Value can be found in the published state on the temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_calibration": NEW_VALUE}. The minimal value is -20 and the maximum value is 20.

Humidity calibration (numeric)

Humidity calibration. Value can be found in the published state on the humidity_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_calibration": NEW_VALUE}. The minimal value is -50 and the maximum value is 50.

Illuminance calibration (numeric)

Illuminance calibration. Value can be found in the published state on the illuminance_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"illuminance_calibration": NEW_VALUE}. The minimal value is -10000 and the maximum value is 10000.

Pir enable (binary)

Enable PIR sensor. Value can be found in the published state on the pir_enable property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"pir_enable": NEW_VALUE}. If value equals true pir enable is ON, if false OFF.

Led enable (binary)

Enabled LED. Value can be found in the published state on the led_enable property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_enable": NEW_VALUE}. If value equals true led enable is ON, if false OFF.

Reporting enable (binary)

Enabled reporting. Value can be found in the published state on the reporting_enable property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"reporting_enable": NEW_VALUE}. If value equals true reporting enable is ON, if false OFF.

Sensitivity (enum)

PIR sensor sensitivity. Value can be found in the published state on the sensitivity property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sensitivity": NEW_VALUE}. The possible values are: low, medium, high.

Keep time (enum)

PIR keep time in seconds. Value can be found in the published state on the keep_time property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"keep_time": NEW_VALUE}. The possible values are: 0, 30, 60, 120, 240.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.