/* Create table for storing *CRTA-BOX* data in *ClickHouse* */
CREATE TABLE IF NOT EXISTS CRTA.log_box3 (
-- Measurement localization in log
`id` UUID DEFAULT generateUUIDv4(1) COMMENT 'Record unique identifier formed in-situ'
-- measurement localization in time
,`timestamp` DateTime('Europe/Moscow') NOT NULL -- streamed tag *timestamp*
-- Measurement localization in space
--- ordering with
,`id_unit` UInt64 NOT NULL COMMENT '*CRTA-BOX* tag *unit_id* - boiler identification code'
,`id_box` UInt16 NOT NULL COMMENT '*CRTA-BOX* tag *apk_id* - *CRTA-BOX* identifier (odd values are associated with boiler unit A, even values - with B)'
,`id_spot` UInt8 NOT NULL COMMENT '*CRTA-BOX* tag *slave_id* - MODBUS standard register that serves as a spot identifier'
---
,`id_sensor` UInt32 NOT NULL COMMENT '*CRTA-BOX* tag *crta_id* - identifier of signal sensor (of telltale)'
-- Measurements
,`value_status` Enum8(
'boiler_up' = 0
,'fault_shortage' = 1
,'fault_unlink' = 2
,'fault_sensor' = 3
,'boiler_down' = 4
,'rupture_param' = 5
,'rupture_level' = 6
,'rupture_multi' = 7
,'device_care' = 8 -- undocumented option
,'fault_log' = 127 -- extra-value formed by *crta-box* streaming process when original value is out of [0-7] range
) NOT NULL COMMENT '*CRTA-BOX* tag *status_modbus* with value interpretation'
,`value_ratio` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *p100_modbus*'
,`value_grade` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *u100_modbus*'
,`preset_ratio` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *ustp_modbus*'
,`preset_grade` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *ustu_modbus*'
,`value_noise` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *sko_modbus*'
,`preset_noise` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *ustskomin_modbus*'
,`value_gain` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *r_modbus*'
,`value_high` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *verh_modbus*'
,`value_low` Int16 NOT NULL COMMENT '*CRTA-BOX* tag *niz_modbus*'
-- Quality
,`StatusCode` UInt32 NOT NULL DEFAULT 0x00A20000
COMMENT '[OPC UA status code](http://www.opcfoundation.org/UA/schemas/StatusCode.csv) formed by *crta-box* streaming process'
) ENGINE = ReplacingMergeTree() -- No duplicates are allowed
PARTITION BY (id_unit, id_box, id_spot, toYYYYMM(`timestamp`))
ORDER BY (id_unit, id_box, id_spot, `timestamp`)