- https://www.home-assistant.io/integrations/utility_meter#yaml-configuration
- https://www.home-assistant.io/integrations/utility_meter#action-utility_meterreset
- https://community.home-assistant.io/t/reset-utility-meter-at-particular-time-of-day/521035/5
At: .storage cat core.config_entries | grep utility_meter
Do not change, just read.
Example json:
{
"created_at": "2024-12-04T10:06:37.652377+00:00",
"data": {},
"disabled_by": null,
"discovery_keys": {},
"domain": "utility_meter",
"entry_id": "01JE8J5KJMCG74S3VVP063W866",
"minor_version": 1,
"modified_at": "2024-12-04T10:06:37.652385+00:00",
"options": {
"always_available": false,
"cycle": "none",
"delta_values": false,
"name": "Invertor Batteries Charge Net kWh (UI)",
"net_consumption": true,
"offset": 0,
"periodically_resetting": false,
"source": "sensor.invertor_battery_average_power_kwh",
"tariffs": []
},
"pref_disable_new_entities": false,
"pref_disable_polling": false,
"source": "user",
"title": "Invertor Batteries Charge Net kWh (UI)",
"unique_id": null,
"version": 2
}
Count the power consumption of the inverter in three instances:
- Battery power Increment\Decrement values -+ kWh
- Can caltulate estimated kWh usage from batteries, how many left, how charged.
- Invertor power Increment\Decrement values -+ kWh
- Can show power losses during charge cycles, just for info.
- Mains Invertor power Usage - simple kWh per time with 0 values during blackouts.
- Can show the full power usage by the invertor from the Main grid
sensor:
# Invertor Battery power Increase\Decrease
# Use in utility meter as NET value
# Count the kWh in the battery on charge\discharge
# used in utility meter id: 'invertor_battery_charge_auto_kwh'
# reset utility meter at full charge
- platform: integration
name: "Invertor Battery Average Power kWh"
source: sensor.easun_easun_battery_average_power
unique_id: invertor_battery_average_power
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Full inverter power comsumption: Increase\Decrease
# Cycle mothtly at utility meter
# Will show unequality in INCR\DECR values
# overtime due to circuit power loses
- platform: integration
name: "Invertor Average Power kWh"
source: sensor.easun_easun_average_inverter_power
unique_id: invertor_average_power
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Full invertor power consumption overall.
# Not NET, can be 0
- platform: integration
name: "Invertor Mains Power kWh"
source: sensor.easun_easun_average_mains_power
unique_id: invertor_mains_power
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Only tracking when charging.
# 100% charged battery = 0 charging power
- platform: integration
name: "Invertor Battery Charging Power kWh"
source: sensor.easun_easun_inverter_charging_power
unique_id: invertor_battery_charging_power
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Make able to consume battery counters
# See packages/sensors/easun_in_out.yaml
# https://community.home-assistant.io/t/home-battery-on-energy-dashboard/463059/6
- platform: integration
name: "EASUN Battery In kWh"
source: sensor.easun_battery_in
unique_id: invertor_battery_charging_kwh
method: left
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
name: "EASUN Battery Out kWh"
source: sensor.easun_battery_out
unique_id: invertor_battery_discharging_kwh
method: left
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
sensor:
## Other
##
- platform: integration
source: sensor.washing_machine_tuya_din_power
unique_id: washing_machine_tuya_din_power_kwh
name: "Washing Machine kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.dishwasher_fridge_power
unique_id: dishwasher_fridge_power_kwh
name: "Dishwasher Fridge kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.conditioner_tuya_din_power
unique_id: conditioner_watt_kwh
name: "Conditioner kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.tuya_cloud_kitchen_1_tyua_power
unique_id: tuya_cloud_kitchen_1_tyua_power_kwh
name: "Kettle kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.coffee_tuya_power
unique_id: coffee_tuya_power_kwh
name: "Coffee kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.custom_1_power
unique_id: custom_1_power_kwh
name: "custom_1_power kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.custom_2_power
unique_id: custom_2_power_kwh
name: "custom_2_power kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.custom_3_power
unique_id: custom_3_power_kwh
name: "custom_3_power kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
- platform: integration
source: sensor.tuya_cloud_towel_power
unique_id: tuya_cloud_towel_power
name: "tuya_cloud_towel_power kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Do not include in total, we have a Fridge+Dishwasher
- platform: integration
source: sensor.dish_washer_watt
unique_id: dish_washer_watt_kwh
name: "Dishwasher kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Counter only for Fridge without dishwasher
# packages/sensors/fridge_without_dishwasher.yaml
- platform: integration
source: sensor.fridge_power
unique_id: fridge_power_kwh
name: "Fridge kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
# Counter for SUM of all power
# packages/sensors/total_consumption_sum.yaml
- platform: integration
source: sensor.total_consumption
unique_id: total_consumption
name: "Total Consumption kWh"
unit_prefix: k
unit_time: h
round: 2
max_sub_interval:
minutes: 1
NOTE: Utility meter uses sensor by its name in snake_case, cannot use unique_id
, dont know why.
Consists of different meters each:
- Check the battery kWh charged and discharged
- NET - can be positive\negative
- reset by automation at battery SoC 100%
- Invertor power usage net, to see power losses
- NET - can be positive\negative
- reset by cycle
- Invertor full power usage from main grid
- can be zero on blackouts
- montly
- weekly
- full
utility_meters
# Invertor meters
# Source is the name of sensor.integration in snake_case
# https://community.home-assistant.io/t/reset-utility-meter-at-particular-time-of-day/521035/5
utility_meter:
# Dont use cycle, reset by Automation: utility_meter.calibrate
# Count +\- of a battery cycle, reset on battery full charge
# by automation.
# source: sensor.easun_easun_battery_average_power
invertor_battery_charge:
source: sensor.invertor_battery_average_power_kwh
name: Invertor Batteries Charge Net kWh
unique_id: invertor_battery_charge_net_kwh
periodically_resetting: true
net_consumption: true
# DISCHARGE
# Same as above, but only as monthly counter and not NET
# use for HA battery system
# source: sensor.easun_easun_battery_average_power
invertor_battery_charge_monthly:
source: sensor.invertor_battery_average_power_kwh
name: Invertor Batteries Charge (monthly) kWh
unique_id: invertor_battery_charge_monthly_kwh
periodically_resetting: true
cycle: monthly
# RECHARGE
# Only active when battery is charging
# use for HA battery system
# source: sensor.easun_easun_inverter_charging_power
invertor_battery_charging_monthly:
source: sensor.invertor_battery_charging_power_kwh
name: Invertor Batteries Charging (monthly) kWh
unique_id: invertor_battery_charging_monthly_kwh
periodically_resetting: true
cycle: monthly
# Count +\- of the inverter cycle, reset monthly
# Will show inequality due to power loss in the system.
# source: sensor.easun_easun_average_inverter_power
invertor_power_net:
source: sensor.invertor_average_power_kwh
name: Invertor Power Consumption Net kWh
unique_id: invertor_power_consumption_net_kwh
net_consumption: true
cycle: monthly
# Just invertor power consumption from the main network
# source: sensor.easun_easun_average_mains_power
invertor_power_monthly_sum:
source: sensor.invertor_mains_power_kwh
name: Invertor Main Power Consumption (monthly)
unique_id: invertor_main_power_monthly
periodically_resetting: true
cycle: monthly
# source: sensor.easun_easun_average_mains_power
invertor_power_weekly_sum:
source: sensor.invertor_mains_power_kwh
name: Invertor Main Power Consumption (weekly)
unique_id: invertor_main_power_weekly
periodically_resetting: true
cycle: weekly
# source: sensor.easun_easun_average_mains_power
invertor_power_all_sum:
source: sensor.invertor_mains_power_kwh
name: Invertor Main Power Consumption (all)
unique_id: invertor_main_power_all
periodically_resetting: true
# https://community.home-assistant.io/t/how-to-use-a-sensor-for-calculate-my-energy-consumption-costs/545131/2
template:
- sensor:
- name: Price kWh
unique_id: electricity_price_uah
icon: mdi:currency-uah
unit_of_measurement: UAH/kWh
state: >
{% if now().hour >= 0 and now().hour < 7 %}
4.32
{% else %}
4.32
{% endif %}
Dishwasher and Fridge both are metered at DIN rail. Dishwasher is also metered by smart socket. Substract Dishwasher wattage from DIN rail to show Frigdge wattage only
# packages/sensors/integration.yaml
template:
- sensor:
# Substract total power if dishwasher from dishwashwer+fridge DIN counter
- name: Fridge power
unique_id: fridge_without_dishwasher
icon: mdi:counter
device_class: power
state_class: measurement
unit_of_measurement: W
state: >
{% if states('sensor.dishwasher_fridge_power')|float >= 0 and states('sensor.tuya_cloud_dishwasher_power')|float >=0 %}
{{ states('sensor.dishwasher_fridge_power')|float - states('sensor.tuya_cloud_dishwasher_power')|float }}
{% else %}0{% endif %}
availability: >
{{ states('sensor.dishwasher_fridge_power')|is_number}}
Collect all actual power meter devices into one
# packages/sensors/integration.yaml
# Include invertor MAINS power when charging and when inverter is on
template:
- sensor:
- name: Total Consumption
icon: mdi:counter
device_class: power
state_class: measurement
unit_of_measurement: W
state: >
{{ states('sensor.easun_easun_average_mains_power')|float(0) +
states('sensor.washing_machine_tuya_din_power')|float(0) +
states('sensor.dishwasher_fridge_power')|float(0) +
states('sensor.conditioner_tuya_din_power')|float(0) +
states('sensor.tuya_cloud_kitchen_1_tyua_power')|float(0) +
states('sensor.coffee_tuya_power')|float(0) +
states('sensor.custom_1_power')|float(0) +
states('sensor.custom_2_power')|float(0) +
states('sensor.custom_3_power')|float(0) +
states('sensor.tuya_cloud_towel_power')|float(0)
}}
availability: >
{{ states('sensor.easun_easun_average_mains_power')|is_number and
states('sensor.washing_machine_tuya_din_power')|is_number and
states('sensor.dishwasher_fridge_power')|is_number and
states('sensor.conditioner_tuya_din_power')|is_number and
states('sensor.tuya_cloud_kitchen_1_tyua_power')|is_number and
states('sensor.coffee_tuya_power')|is_number and
states('sensor.custom_1_power')|is_number and
states('sensor.custom_2_power')|is_number and
states('sensor.custom_3_power')|is_number and
states('sensor.tuya_cloud_towel_power')|is_number
}}
Read:
- https://www.home-assistant.io/integrations/template/#sensor
- https://developers.home-assistant.io/docs/core/entity/sensor/#available-state-classes
- https://www.home-assistant.io/integrations/sensor#device-class
- https://www.home-assistant.io/docs/energy/faq/#troubleshooting-missing-entities
- https://community.home-assistant.io/t/home-battery-on-energy-dashboard/463059/2
Seems OK:
Preprequisits:
- Make a template sensor to filter out negative float numbers and other cleaning (below)
- Based on actual invertor sensor fro, ESP32 module:
sensor.easun_easun_battery_average_power
- Based on actual invertor sensor fro, ESP32 module:
- Make Invertor counter for Wattage in or out of batteries: see
- Based on the step 1. from current module:
sensor.easun_battery_in
andsensor.easun_battery_out
- Based on the step 1. from current module:
- Add in the battery section at energy page
Invertor reports a battery charge\discharge as a counter with pos\negative values. Convert negative value to ABS positive and report as a separate discharge sensor. Report charge sensor for convinience by sorting out any negative float by reporting zero instead.
# https://community.home-assistant.io/t/home-battery-on-energy-dashboard/463059/6
template:
- sensor:
# If positive int - report, show 0 for a negative int
# easun_battery_in:
- name: EASUN Battery In
unique_id: easun_battery_in
icon: mdi:battery-charging
state_class: measurement
device_class: power
unit_of_measurement: W
state: >
{% if states('sensor.easun_easun_battery_average_power')|float >= 0 %}
{{ states('sensor.easun_easun_battery_average_power')|float }}
{% else %}0{% endif %}
availability: >
{{ states('sensor.easun_easun_battery_average_power')|is_number}}
# If negative int - onvert to positive, show 0 for positive int
# easun_battery_out:
- name: EASUN Battery Out
unique_id: easun_battery_out
icon: mdi:battery-arrow-down
state_class: measurement
device_class: power
unit_of_measurement: W
state: >
{% if states('sensor.easun_easun_battery_average_power')|float < 0 %}
{{ states('sensor.easun_easun_battery_average_power')|float|abs }}
{% else %}0{% endif %}
availability: >