title description addedAt pageClass
Immax 07047L control via MQTT
Integrate your Immax 07047L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2020-09-30 20:52:56 UTC
device-page

Immax 07047L

Model 07047L
Vendor Immax
Description Intelligent motion sensor
Exposes occupancy, battery_low, tamper, battery, temperature, illuminance, illuminance_lux, humidity, linkquality
Picture Immax 07047L

Notes

Pairing

Pair the sensor to Zigbee2MQTT by pressing the pair button 3 seconds.

Detection cooldown

Cooldown of detection is around 1 min. In other words; 1 min after last published detection (and trigger no longer present) occupancy will be published as false.

Options

How to use device type specific configuration

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

  • illuminance_lux_calibration: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

Exposes

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It's not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Battery low (binary)

Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Tamper (binary)

Indicates whether the device is tampered. Value can be found in the published state on the tamper property. It's not possible to read (/get) or write (/set) this value. If value equals true tamper is ON, if false OFF.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Illuminance (numeric)

Raw measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value.

Illuminance (lux) (numeric)

Measured illuminance in lux. Value can be found in the published state on the illuminance_lux property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.