title | description | addedAt | pageClass |
---|---|---|---|
Immax 07047L control via MQTT |
Integrate your Immax 07047L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2020-09-30 20:52:56 UTC |
device-page |
Model | 07047L |
Vendor | Immax |
Description | Intelligent motion sensor |
Exposes | occupancy, battery_low, tamper, battery, temperature, illuminance, illuminance_lux, humidity, linkquality |
Picture |
Pair the sensor to Zigbee2MQTT by pressing the pair button 3 seconds.
Cooldown of detection is around 1 min. In other words; 1 min after last published detection (and trigger no longer present) occupancy will be published as false.
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number. -
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number. -
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Indicates whether the device detected occupancy.
Value can be found in the published state on the occupancy
property.
It's not possible to read (/get
) or write (/set
) this value.
If value equals true
occupancy is ON, if false
OFF.
Indicates if the battery of this device is almost empty.
Value can be found in the published state on the battery_low
property.
It's not possible to read (/get
) or write (/set
) this value.
If value equals true
battery low is ON, if false
OFF.
Indicates whether the device is tampered.
Value can be found in the published state on the tamper
property.
It's not possible to read (/get
) or write (/set
) this value.
If value equals true
tamper is ON, if false
OFF.
Remaining battery in %, can take up to 24 hours before reported.
Value can be found in the published state on the battery
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Measured temperature value.
Value can be found in the published state on the temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Raw measured illuminance.
Value can be found in the published state on the illuminance
property.
It's not possible to read (/get
) or write (/set
) this value.
Measured illuminance in lux.
Value can be found in the published state on the illuminance_lux
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is lx
.
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.