use crate::celsius;
use truma_ekit_core::{ekit::EKitUserRunMode, types::Temperature};
/// The threshold for running the controller at full capacity.
/// If the temperature difference is below this value, the controller will be run at half capacity.
const FULL_CAPACITY_TRESHOLD: Temperature = celsius(1.5);
pub struct Thermostat {
requested_temperature: Temperature,
}
impl Thermostat {
pub fn new(requested_temperature: Temperature) -> Self {
Thermostat {
requested_temperature,
}
}
/// Get the requested temperature.
pub fn requested_temperature(&self) -> Temperature {
self.requested_temperature
}
/// Set the requested temperature.
pub fn set_requested_temperature(&mut self, temperature: Temperature) {
self.requested_temperature = temperature;
}
/// Get the suggested run mode for the given actual temperature.
pub fn suggested_ekit_run_mode(&self, actual_temperature: Temperature) -> EKitUserRunMode {
if actual_temperature >= self.requested_temperature {
// the actual temperature is equal to or higher than the requested temperature, turn off the heating
EKitUserRunMode::Off
} else {
// the actual temperature is less than the requested temperature, turn on the heating
let temp_diff = self.requested_temperature - actual_temperature;
if temp_diff < FULL_CAPACITY_TRESHOLD {
// run the heating at half capacity
EKitUserRunMode::Half
} else {
// run the heating at full capacity
EKitUserRunMode::Full
}
}
}
}
#[cfg(test)]
mod tests {
use super::*;
use truma_ekit_core::util::celsius;
#[test]
fn actual_temperature_lower_than_requested_temperature() {
let thermostat = Thermostat::new(celsius(21.0));
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(20.9)),
EKitUserRunMode::Half
);
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(20.0)),
EKitUserRunMode::Half
);
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(19.6)),
EKitUserRunMode::Half
);
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(19.5)),
EKitUserRunMode::Full
);
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(0.0)),
EKitUserRunMode::Full
);
assert_eq!(
thermostat.suggested_ekit_run_mode(celsius(-10.0)),
EKitUserRunMode::Full
);
}
#[test]
fn actual_temperature_equal_to_requested_temperature() {
assert_eq!(
Thermostat::new(celsius(0.0)).suggested_ekit_run_mode(celsius(0.0)),
EKitUserRunMode::Off
);
assert_eq!(
Thermostat::new(celsius(21.0)).suggested_ekit_run_mode(celsius(21.0)),
EKitUserRunMode::Off
);
}
#[test]
fn actual_temperature_higher_than_requested_temperature() {
assert_eq!(
Thermostat::new(celsius(21.0)).suggested_ekit_run_mode(celsius(21.1)),
EKitUserRunMode::Off
);
assert_eq!(
Thermostat::new(celsius(0.0)).suggested_ekit_run_mode(celsius(1.0)),
EKitUserRunMode::Off
);
}
}