Notifications
You must be signed in to change notification settings - Fork 0
/
ercf_parameters.cfg
153 lines (131 loc) · 11.3 KB
/
ercf_parameters.cfg
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
[ercf]
# Servo configuration -----------------------------------------------------------------------------------------------------
servo_up_angle: 31 # Default: MG90S servo: Up=30 ; SAVOX SH0255MG: Up=140
servo_down_angle: 140 # Default: MG90S servo: Down=140 ; SAVOX SH0255MG: Down=30
# Gear stepper load/unload speeds ------------------------------------------------------------------------------------------
# Long moves are faster than the small ones and used for the bulk of the bowden movement
# 100mm/s should be "quiet" with the NEMA14 motor or a NEMA17 pancake, but you can go lower for really low noise
long_moves_speed: 150 # mm/s. Conservative value is 100mm/s, Max around 300mm/s
short_moves_speed: 50 # mm/s. Conservative value is 35mm/s. Max around 100mm/s
# Logging ------------------------------------------------------------------------------------------------------------------
# log_level & logfile_level can be set to one of (0 = essential, 1 = info, 2 = debug, 3 = trace, 4 = developer)
# Generally you can keep console logging to a minimal whilst still sending debug output to the ercf.log file
# Increasing the console log level is only really useful during initial setup to save having to constantly open the log file
log_level: 1
logfile_level: 3 # Can also be set to -1 to disable log file completely
log_statistics: 1 # 1 to log statistics on every toolchange, 0 to disable (but still recorded)
log_visual: 1 # 1 log visual representation of filament, 2 shortened KlipperScreen friendly, 0 disable
startup_status: 1 # Whether to log tool to gate status on startup, 1 = summary, 2 = full, 0 = disable
# Bowden tube movement -----------------------------------------------------------------------------------------------------
# Base value for the loading length used by the auto-calibration macro. Please use a value SMALLER than the real reverse
# bowden length (by about 30-40mm). This is ONLY used during calibration, and has no impact on normal running after calibration
calibration_bowden_length: 1870
#
# If you are getting "timer too close" errors, increase the number of moves used during long loading and unloading moves
num_moves: 1 # Number of moves to make when loading or unloading bowden
#
# If enabled, the driver will "believe" the encoder reading and make correction moves to bring the filament to the desired
# end of bowden position. This is useful is you suspect slippage on high speed loading (but requires accurate encoder)
# If disabled, the gear stepper will be solely responsible for filament positioning in bowden (requires minimal friction)
apply_bowden_correction: 0
# Filament homing, loading and unloading controls -------------------------------------------------------------------------
# If you have a toolhead sensor for filament homing:
toolhead_homing_max: 35 # Maximum distance to advance in order to attempt to home to toolhead sensor (default 20)
toolhead_homing_step: 1.0 # Step size to use when homing to the toolhead sensor (default 1)
#
# Options without toolhead sensor (but still needed for calibration with toolhead sensor)
extruder_homing_max: 50 # Maximum distance to advance in order to attempt to home the extruder
extruder_homing_step: 2.0 # Step size to use when homing to the extruder with collision detection (default 2)
#
# For accurate homing and to avoid grinding, tune the gear stepper current reduction (currently TMC2209 only)
# To ensure no skipping during fast tip-forming moves, tune the extruder current increase (currently TMC2209 only)
extruder_homing_current: 25 # Percentage of gear_stepper current (20%-100%) to use when homing to extruder homing (100 to disable)
extruder_form_tip_current: 100 # Percentage of extruder current (100%-150%) to use when forming tip (100 to disable)
#
# How far (mm) to run gear_stepper and extruder together in sync on load and unload. This will make loading and unloading
# more reliable and will act as a "hair pulling" step on unload. These settings are optional - use 0 to disable
# Non zero value for 'sync_load_length' will synchronize the whole homing distance if toolhead sensor is installed
sync_load_length: 80 # mm of synchronized extruder loading at entry to extruder
sync_unload_length: 80 # mm of synchronized movement at start of bowden unloading
#
# This is the distance of the final filament load from the homing point to the nozzle
# If homing to toolhead sensor this will be the distance from the toolhead sensor to the nozzle
# If extruder homing it will be the distance from the extruder gears (end of bowden) to the nozzle
#
# This value can be determined by manually inserting filament to your homing point (extruder gears or toolhead sensor)
# and advancing it 1-2mm at a time until it starts to extrude from the nozzle. Subtract 1-2mm from that distance distance
# to get this value. If you have large gaps in your purge tower, increase this value. If you have blobs, reduce this value.
# This value will depend on your extruder, hotend and nozzle setup.
#home_position_to_nozzle: 72 # E.g. Revo Voron with CW2 extruder using extruder homing (62 with toolhead sensor)
home_position_to_nozzle: 71 # Afterburner, Galileo v1, Dragon HF
#
# Advanced and optional. If you regularly switch between sensorless and toolhead sensor or you want to optimize extruder
# unload when using toolhead sensor you can override 'home_position_to_nozzle' with these more specific values
# (Note that the difference between these two represents the extruder to sensor distance and is used as the final
# unload distance from extruder. An accurate setting can reduce tip noise/grinding on exit from extruder)
#extruder_to_nozzle: 72 # E.g. Revo Voron with CW2 extruder using extruder homing
#sensor_to_nozzle: 62 # E.g. Revo Voron with CW2 extruder using toolhead sensor homing
# Selector gate positions -------------------------------------------------------------------------------------------------
# The position of each gate (tool) on the selector. See the manual for setting these values
colorselector: 4.0, 24.8, 45.6, 71.2, 92.0, 113.6
#
# Optional position of the filament bypass (special version of separator block). Comment out or set to 0 to disable
#bypass_selector: 122.8 # Set to your measured position
# This group of settings collectively form the default gate map which can be updated with the `ERCF_SET_GATE_MAP` command
# or similar commands that determine gate status. They must all be the same length at the number of gates (0 .. n)
# Note that these are the defaults and will be overriden by saved values in ercf_vars.cfg.
#
#
# Whether gate has filament available (1=available, 0=empty). If not specified or commented out all gates are unknown (but available)
#gate_status: 1, 0, 0, 0, 0, 0
#
# Similarly this specifies the material type present in the gate. If not specified for commented out the name will be empty
#gate_material: PLA, PETG, ABS, PLA+, ABS, ABS
#
# Similarly this specifies the color of the filament in each gate. If not specified for commented out the color will be default
#gate_color: red, orange, yellow, green, blue, indigo
# The default mapping for tool to gate. If not specified or commented out the mapping will default to Tx = Gate #x
# This must be the same length at the number of gates.
# Note that this will be overriden by a saved value in ercf_vars.cfg. ERCF_RESET_TTG_MAP will revert to these default values
tool_to_gate_map: 0, 1, 2, 3, 4, 5
# Options and Features ----------------------------------------------------------------------------------------------------
# Selector operation. If configured for sensorless homing ERCF can detect blocked filament path and try to recover automatically
# Sensorless still requires the physical endstop switch to be configured as the endstop on the (non intuiative) GEAR stepper
sensorless_selector: 1 # 0 = use only a physical endstop, 1 = use advanced sensorless selector homing
enable_clog_detection: 2 # 0 = disable, 1 = static length clog detection, 2 = automatic length clog detection
enable_endless_spool: 0 # 0 = disable endless spool, 1 = enable endless spool (requires clog detection)
# If endless spool is turned on, you should define a list of EndlessSpool groups here, one entry for each gate in your ERCF
# when filament runs out on a gate, it will switch to the next gate with the same group number
# for example, if set to 1, 2, 3, 1, 2, 3, 1, 2, 3 on a 9 cart ERCF, and a runout occurs on gate #0
# the ERCF will switch to using gate #3 and then gate #6 automatically remapping the tool as it goes.
# Note that this will be overriden by a saved value in ercf_vars.cfg if modified with ERCF_ENDLESS_SPOOL_GROUPS command
#endless_spool_groups: 1, 2, 3, 1, 2, 3
# Advanced: ERCF can auto-initialize based on previous persisted state. There are 5 levels with each level bringing in
# additional state information requiring progressively less inital setup. The higher level assume that you don't touch
# ERCF while it is offline and it can come back to life exactly where it left off! If you do touch it or get confused
# then issue an appropriate reset command (E.g. ERCF_RESET) to get state back to the defaults.
# Enabling `startup_status` is recommended if you use persisted state at level 2 and above
# Levels: 0 = start fresh every time (the former default behavior)
# 1 = restore persisted endless spool groups
# 2 = additionally restore persisted tool-to-gate mapping
# 3 = additionally restore persisted gate status (filament availability and color)
# 4 = additionally restore persisted tool, gate and filament position!
persistence_level: 0
# Advanced: Configurable, but fairly fixed values ------------------------------------------------------------------------
timeout_pause: 72000 # Time out used by the ERCF_PAUSE
disable_heater: 600 # Delay after which the hotend heater is disabled in the ERCF_PAUSE state
min_temp_extruder: 200 # Used to ensure we can move the extruder and form tips
unload_buffer: 60 # Amount to reduce the fast unload so that accurate encoder unload has room to operate
load_encoder_retries: 2 # Number of times ERCF will attempt to grab the filament on initial load (max 5)
parking_distance: 23.0 # Controls how close to the gate washer the filament is parked (distance from encoder, range=12-30)
ignore_extruder_load_error: 0 # Whether the detection of successful extruder load is considered an error or warning (ignored)
load_bowden_tolerance: 8.0 # When using 'apply_bowden_correction' this is how close the correction moves will attempt to get on load
delay_servo_release: 2.0 # Delay release on servo by (mm) when not using synchronous load
homing_method: 0 # EXPERIMENTAL. Filament homing method if not using toolhead sensor. 0=collision detection, 1=stallguard
z_hop_height: 5 # Height in mm of z_hop move on pause or runout to avoid blob on print
z_hop_speed: 15 # mm/s Speed of z_hop move
sync_load_speed: 10 # mm/s speed of synchronized extruder load moves
sync_unload_speed: 10 # mm/s speed of synchronized extruder unload moves
nozzle_load_speed: 15 # mm/s speed of load move inside extruder from homing position to meltzone
nozzle_unload_speed: 20 # mm/s speed of unload moves inside of extruder (very initial move from meltzone is 50% of this)
servo_duration: 0.2 # Duration of PWM burst sent to servo (automatically turns off)