# Upgrading management and managed nodes with different CSM versions using IUF | ||
|
||
For certain use cases, there may be a need to combine different recipes of CSM to bring up the | ||
management and managed nodes. For example, if a feature which supports a specific | ||
CPU architecture for managed nodes is needed and that is present in a different recipe of CSM | ||
than the version of CSM that will be run on management nodes. | ||
|
||
## Procedure | ||
|
||
1. Decide the recipes for management and managed nodes. For example, use recipe `a.b.c`, | ||
which contains CSM version `1.5.x` for managed nodes and use recipe `x.y.z`, which contains | ||
CSM version `1.6.x`, for management nodes. | ||
|
||
1. Ensure that the CSM cluster is operational with the lowest among the selected recipes for both | ||
management and managed nodes. | ||
|
||
If it is necessary to upgrade CSM to the lowest among the selected recipes, then | ||
use the [Upgrade CSM and additional products with IUF](../operations/iuf/workflows/upgrade_csm_and_additional_products_with_iuf.md) procedure to upgrade CSM. In the | ||
above example, the upgrade would be to recipe `a.b.c`, which contains CSM version | ||
`1.5.x`, for both management and managed nodes. | ||
|
||
1. Go through the `product_vars.yaml` file of both the recipes and come up with a set | ||
of products and versions across the recipes which have to be upgraded for CSM version **`1.6.x`**. | ||
|
||
1. Use the [Upgrade CSM and additional products with IUF](../operations/iuf/workflows/upgrade_csm_and_additional_products_with_iuf.md) procedure to upgrade CSM until | ||
[step 9, Managed rollout](../operations/iuf/workflows/managed_rollout.md), skip section | ||
"2.2 Compute Nodes". That is, do not upgrade compute nodes to the recipe `x.y.z` | ||
with CSM version `1.6.x` in order to keep the compute nodes on the `a.b.c` recipe | ||
with CSM version `1.5.x`. | ||
|
||
## Post install Testing | ||
|
||
Execute the NCN health checks to validate that management nodes are executing correctly. | ||
|
||
```bash | ||
/opt/cray/tests/install/ncn/automated/ncn-healthcheck-master | ||
/opt/cray/tests/install/ncn/automated/ncn-healthcheck-worker | ||
/opt/cray/tests/install/ncn/automated/ncn-healthcheck-storage | ||
/opt/cray/tests/install/ncn/automated/ncn-kubernetes-checks | ||
``` | ||
|
||
Execute the post install checks to validate that the managed nodes are executing correctly. | ||
Refer to [Post Install Check](../operations/iuf/stages/post_install_check.md) on | ||
running post install checks. |