Skip to content

Latest commit

 

History

History
36 lines (22 loc) · 1.19 KB

FEM_ConstraintInitialTemperature.md

File metadata and controls

36 lines (22 loc) · 1.19 KB

  • GuiCommand: Name:FEM ConstraintInitialTemperature MenuLocation:Model → Thermal Constraints → Constraint initial temperature Workbenches:FEM SeeAlso:FEM tutorial

FEM ConstraintInitialTemperature

Description

Creates an initial temperature constraint for a thermo-mechanical analysis.

Usage

  1. There are several ways to invoke the command:
  2. Enter an initial temperature value for the analysis.

Limitations

The constraint applies the initial temperature to all nodes in the FEA model

Notes

  1. The constraint uses the **INITIAL CONDITIONS card in CalculiX. The initial temperature constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node215.html

{{FEM Tools navi}}


documentation index > FEM ConstraintInitialTemperature