- Slide the VEML sensor mount into Structure Panel B with the untabbed side first. Mount can be on the left or right side.
Figure 1: Rendering of Structure Panel B with VEML sensor mount.
- Use two M2.5 bolts and nuts to fasten the VML sensor to the mount with the sensor pointed away from the rounded cutouts.
Figure 2: Left: Rendering of Structure Panel B with VEML sensor mount and VEML sensor. Right: Photo of VEML sensor mounted on Structure Panel B with solar panel in place.
- Unscrew two of the mounting nuts from the solar panel and side into the top in the notches for Structure Panel B. The wire should be on the same side of Structure Panel B as the slot for the VML sensor. Re-attach the mounting nuts.
Figure 3: Structure Panel B with VEML and solar panel mounted.
- Turn Structure Panel A horizontal, and slide into the large gap in Structure Panel B until the bottom middle notch is over Structure Panel A.
Figure 5: Structure Panel A being slotted into Structure Panel B.
- Rotate Structure Panel A so that it is vertical, and slide until the notches for the two panels are snug.
Figure 6: Left: Rendering of Structure Panels A and B in place with solar panel. Red square indicates cable location for the solar panel. Right: Photo of Structure Panels A and B in place with solar panel. Note VEML sensor should already be mounted.
- Place the SHT31 sensor on Structure Panel A where there are notches for the zip ties so that the cable is away from the center, and use two zip ties to secure at notches (see Figure 4).
Figure 7: SHT31 sensor in place with solar panel and enclosure (to be added later).