Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Custom template paths for Modelica output #679

Open
PGorzalka opened this issue Feb 25, 2021 · 1 comment
Open

Custom template paths for Modelica output #679

PGorzalka opened this issue Feb 25, 2021 · 1 comment

Comments

@PGorzalka
Copy link
Contributor

PGorzalka commented Feb 25, 2021

What is the problem?

  • The current implementation restricts templates to files located in pre-defined paths within TEASER's folder structure

Why do we want to solve it?

  • For custom applications, it would be nice to switch between different Multizone and ThermalZone templates

How do we want to solve it?

  • Add an optional parameter to the export_aixlib function that specifies a path to a template on the local hard drive

Additional context

This issue is related to a case-specific application of AixLib (ROM) and TEASER which also includes issue #1080 in AixLib (others may follow after email consultations)

@PGorzalka
Copy link
Contributor Author

Discussion with @DaJansenGit (see here) lead to the envisaged contributions of

  • non-constant soil temperature
  • interzonal heat exchange (TEASER and AixLib)
  • custom template paths for Modelica output in TEASER as described in this issue
  • a new possibility to estimate interior wall area (relates to Check calculation of interior area #474 )