Releases: SiLab-Bonn/pyBAR
Releases · SiLab-Bonn/pyBAR
v3.1.2
v2.2.2
v3.1.1
- Compatibility with latest Anaconda Python
- Compatibility with basil>=2.4.12
- Compatibility with EUDAQ>=1.7
- Ignoring RX errors in hot pixel tuning
- Fixed ExtTriggerScan got stucked when run a second time
- Fixed TLU tuning script
- Fixed plotting issues in case of no data
- Fixed not writing remaining data in FIFO
- Added general
configure_fe
andreset_fe
run configuration parameter - Updated GDAC tuning algorithm to reliably tune to desired threshold value
- Many other cleanups and smaller improvements
v2.2.1
This release is providing single chip support only!
- Compatibility with latest Anaconda Python
- Compatibility with basil>=2.4.12
- Compatibility with EUDAQ>=1.7
- Ignoring RX errors in hot pixel tuning
- Fixed TLU tuning script
- Fixed plotting issues in case of no data
- Fixed not writing remaining data in FIFO
- Added general
configure_fe
andreset_fe
run configuration parameter - Updated GDAC tuning algorithm to reliably tune to desired threshold value
- Many other cleanups and smaller improvements
v3.1.0
- adding context manager to Fei4RunBase to manage resource
- adding firmware for SHiP experiment
- keeping TLU/TRIGGER FSM busy when RX FIFO is not empty (all firmwares)
- adding write intervals to reduce disk usage
- fixing threshold baseline tuning and standard GDAC tuning
- fixing IPython issues with pyplot
- adjusting search paths for configuration files
- adding no data timeout for each FEI4 detector
- fixing many other issues and annoyances
- code cleanup (firmware and software)
v2.2.0
- using FIFO readout module from pyBAR v3.x.
- using write intervals to reduce disk usage
- fixing threshold baseline tuning and standard GDAC tuning
- fixing IPython issues with pyplot (remove pyplot)
- adjusting search paths for configuration files
- fixing many other issues and annoyances
- code cleanup
v2.1.1
- fixing TLU FSM was not enabled
v3.0.2
- cleanup
- remove Mimosa26 support from pyBAR -> https://github.com/SiLab-Bonn/pymosa
- fix online monitor
- fix default scan parameters for some scans
- enable threading by default while tuning
v3.0.1
- fixing RX reset and preserving register settings
v3.0.0
- supporting multiple readout boards
- supporting multi-chip modules (e.g., single, dual, quad module, and any combination of those)
- supporting parallel tuning of modules attached to individual TX (CMD) lines
- supporting multiple trigger inputs
- preserving scan/tune/calibration scripts