Notifications
You must be signed in to change notification settings - Fork 108
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #1482 from MichaelDvP/dev2
Testbuild
- Loading branch information
Showing
67 changed files
with
3,586 additions
and
2,478 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,38 +1,25 @@ | ||
# Changelog | ||
|
||
## [3.6.3] | ||
## [3.6.5] | ||
|
||
## **IMPORTANT! BREAKING CHANGES** | ||
|
||
Writeable Text entities have moved from type `sensor` to `text` in Home Assistant to make them also editable within an HA dashboard. Examples are `datetime`, `holidays`, `switchtime`, `vacations`, `maintenancedate`... You will need to manually remove any old discovery topics from your MQTT broker using an application like MQTT Explorer. | ||
- new device WATER shows dhw entities from MM100 and SM100 in dhw setting | ||
|
||
## Added | ||
|
||
- humidity for ventilation devices | ||
- telegrams for RC100H, hc2, etc. (seen on discord, not tested) | ||
- names for BC400, GB192i.2, read temperatures for low loss header and heatblock [#1317](https://github.com/emsesp/EMS-ESP32/discussions/1317) | ||
- option for `forceheatingoff` [#1262](https://github.com/emsesp/EMS-ESP32/issues/1262) | ||
- remote thermostat emulation RC100H for RC3xx [#1278](https://github.com/emsesp/EMS-ESP32/discussions/1278) | ||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329) | ||
- HA discovery for writeable text entities [#1337](https://github.com/emsesp/EMS-ESP32/pull/1377) | ||
- autodetect board_profile, store in nvs, add telnet command option, add E32V2 | ||
- heatpump high res energy counters [#1348, #1349. #1350](https://github.com/emsesp/EMS-ESP32/issues/1348) | ||
- optional bssid in network settings | ||
- extension module EM100 [#1315](https://github.com/emsesp/EMS-ESP32/discussions/1315) | ||
- digital_out with new options for polarity and startup state | ||
- added 'system allvalues' command that dumps all the EMS device values, plus sensors and any custom entities | ||
- some more entities for dhw with SM100 module | ||
- thermostat boost mode and boost time [#1446](https://github.com/emsesp/EMS-ESP32/issues/1446) | ||
- heatpump energy meters [#1463](https://github.com/emsesp/EMS-ESP32/issues/1463) | ||
- heatpump max power [#1475](https://github.com/emsesp/EMS-ESP32/issues/1475) | ||
- checkbox for MQTT-TLS enable [#1474](https://github.com/emsesp/EMS-ESP32/issues/1474) | ||
|
||
## Fixed | ||
|
||
- remove command `remoteseltemp`, thermostat accept it only from remote thermostat | ||
- shower_data MQTT payload contains the timestamp [#1329](https://github.com/emsesp/EMS-ESP32/issues/1329) | ||
- fixed helper text in Web Device Entity dialog box for numerical ranges | ||
- MQTT base with paths not working in HA [#1393](https://github.com/emsesp/EMS-ESP32/issues/1393) | ||
- exhaust temperature for some boilers | ||
- add back boil2hyst [#1477](https://github.com/emsesp/EMS-ESP32/issues/1477) | ||
|
||
## Changed | ||
|
||
- update to platform 6.4.0, arduino 2.0.14 / idf 4.4.6 | ||
- small changes for arduino 3.0.0 / idf 5.1 compatibility (not backward compatible to platform 6.3.2 and before) | ||
- AP start after 10 sec, stay until station/eth connected | ||
- tested wifi-all-channel-scan (3.6.3-dev4 a-e), removed again because of connect issues | ||
- mqtt disconnect stops queue | ||
- use flag for BC400 compatible thermostats, manage different mode settings | ||
- HA don't set entity_category to Diagnostic/Configuration for EMS entities [#1459](https://github.com/emsesp/EMS-ESP32/discussions/1459) |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.