Strong Ground Motion Signal Analysis for Engineers and Seismology

Author : Maria LANCIERI

The python class signal_analysis computes a set of intensity measures (IM) caracterising the seismic signal for earthquake engineering.

The class is distributed with several example routines to show its potential in reading several input formats (ORFEUS, K-Net and KiK-net Bosai networks), example based on mseed and sac formats are distributed too.

Dependencies

The class requires scipy, obspy, numpy and stockwell packages.

For GMPE option OpenQuake GSIM hazardlib is required as well. If the user is not interested in GMPE and/or encounter issues with OpenQuake instation the computegmpe and read_gmpeinput routines can be commented with no consequences on the other functions.

The exemple routines require pickel glob pyproj packages

Class purposes

Compute baseline corrected accelerograms to be used as input for dynamic structure response analysis. It computes a suite of classical intensity measures. The class can handle different data format and units.

What the class does not do

The pre-processing of the waveform to establish the cut interval or the baseline correction parameters.

The class works with the user input: real or synthetic data.

The class is designed to work with a single component per time, it does not combine component computing rot50, geometric mean and so on. In the exemple routines a data structure allowing to easly recompute the combined parameter is suggested.

Class structure

The structure of the signal_analysis class is the following:

class structure

read_knet() or read_orfeus() and baseline() routines are mandatory since they create the self and the tr (trace) object with the attributes used in the class function.

Content of tr object with attributes

Header information on seismic event

tr.hdr.evname tr.hdr.evid tr.hdr.evdate tr.hdr.evtime tr.hdr.evla tr.hdr.evlo tr.hdr.evdp tr.hdr.mw tr.hdr.ml tr.hdr.foca

Mandatory station attributes

tr.stats.network tr.stats.station tr.stats.location tr.stats.channel

Further station information

tr.stats.stnm
tr.stats.sac.stla tr.stats.sac.stlo tr.stats.sac.stelv tr.stats.vs30 tr.stats.sclass tr.stats.epi

Mandatory trace attributes

tr.stats.delta
tr.stats.npts
tr.data

If mseed or SAC format are used, it is important to creare a tr attribute with the mandatory information, two exemples are available in the exemple routines. The tr object is indeed inspired the obspy.read output.

In any case the routine baseline must be evoked since it creates the self object with waveform amplitude (in acceleration, velocity and displacement), time, sample interval. If manual processed waveforms are used

How to use the class

import signal_analysis
tool = signal_analysis.mytools()
tr = tool.read_orfeus(tracename)  # `tracename` is a string 
delta = tr.stats.delta
npts  = tr.stats.npts
time = np.arange(npts)*delta

time,acc,vel,spo, fminu, fmaxu = tool.baseline(tr.data,time,cutmin=cut[cname][0],cutmax=cut[cutname][1],const=1 )  

pga = tool.pga()    
pgv = tool.pgv()    
pgd = tool.pgd() 
scav,scavtime, cav,cavtime, bcav, bcavtime = tool.cav(unit='cm/s2')    
ari,aritime,husid = tool.arias(unit='cm/s2')    
stock,X,Y,extent =  tool.stockwell(acc,time)    
freq =  np.logspace(-1,np.log10(50),100)    
psa, psv, freq = tool.response(freq=freq) 
spi  = tool.specint('sa')    
Hous = tool.specint('psv')

# the following line is an exemple for power density function computation, for a single line it is not worth to define a class function.
freq_welch, trace_welch = welch(acc, fs=(1/delta),nperseg=1024)

Technical and scientific overview of the signal_analysis class functions

baseline

 def baseline (self,acc,time,**kwargs):
        """
        acc  : array 
        time : array
        A bandpass Butterworth filter zero phase shift is applied, the kwargs are:
        fmin   : the high-pass cutoff filter frequency, default 0.1
        fmax   : the low-pass  cutoff filter frequency, default Nyquist frequency
        npoles :number of poles, default 4
        
        coswin : cosine windowing lenght in percentage of signal length, default is 0.1
        
        const : normalization value (i.e. 9.8), default is 1 it is applied only to acceleration
    
        cutmin : cut window beg time, default time[0]
        cutmax : cut window beg time, default time[-1]
        
        base : "Non" if MP waveform, type=str defaul "Yes"
    
        """

The baseline procedure is the following

The class has been adapted to work with velocity signals (mseed from broad-band networks), in this case a baseline_vel() function must be used to compute acceleration and displacement.

Scientific Warning on Baseline Correction

Some waveforms require to filter the velocity and/or displaccement as well, in my opinion this is a strong signal manipulation that has to be carefully checked and it can not be performed automatically. On the basis of my experiece, difficulties in correcting waveforms are related to:

  • missed samples;
  • bad installation condition (sensor shift, objects falling near the sensor during the shaking);
  • finite displacement.

Each of this case requires specific strategies of signal correction, none of them is implemented in signal_analysis.

Indeed, to allow the user compute the intensity measure on manually processed waveforms, the baseline() function can be used with the kwarg option base="Non"

A further warining on waveforms with finite displacement: the baseline() function is designed to output accelerograms for structural computing forcing displacement to go to zero in the end of trace. It is not suited to study records affected by finite displacement; if the baseline procedure is applied in this specific case the displacement waveform will be caracterized by a low frequency trend occurring before the P-wave arrival.

When baseline_ve() is used it is possible to filter velocity waveforms.

It is not suitable to apply baseline twice, for these reason, when manual

Peak amplitude (PGA, PGV and PGD)

The functions pga() pgv() pgd() read the corrected acceleration, velocity and displacement and output the absolute maximum.

The Cumulative Absolute Velocity (CAV)

  """
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
       CAV calculation    
       EPRI 1988 -> CAV
       RFS V.II  -> Bracketed CAV
       EPRI 2006 -> Standardizd CAV
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    """

    def cav (self, **kwargs):
    
        """
        the kwargs unit :  string g,cm/s2 or m/s2 
        since the baseline normalize the acceleration the default value is g

        the 3 CAV are computed
        scav :  standardized CAV 
        cav  :  classical cav
        bcav : bracketed duration cav (5% of g)
        """    
      unit = "g"
        for key in kwargs:
            if key == "unit":    unit = kwargs[key] 

        if unit == "g"       :  const = 1
        elif unit == "cm/s2" :  const = 980
        elif unit == "m/s2"  : const = 9.8

        
        acc = self.acc/const

The CAV function compute the CAV following the 3 definitions of EPRI 1988, French regulatory code RFS V.II 2005 and the EPRI 2006. The output is in [gs], the amplitude normalization constant const is computed as a function of units of the input accelerogram for this reason the unit kwargs is mandatory.

The 3 definitions of CAV parameters

The CAV parameter has been first introduced by the EPRI in 1988. It is defined as the integral of the absolute value of acceleration. To make the CAV computing less dependent on the signal cuts (in 1988 no continous records were available) two further CAV definition have been intoduced: the brackted CAV $CAV_{BD}$ and the standardized CAV ($SCAV$).

The $CAV_{BD}$ is defined as the integral of absolute value of the acceleration over the time window where the acceleration amplitude is larger than 5% of g. For weak motions it can be equal to zero.

The $SCAV$ is the integral of the absolute value of the accelerogram computed over slinding, non overlaping, windows of 1 second of duration if the acceleration amplitude in the window is greater than 0.025 g. For weak motions it can be equal to zero.

A conceptual sketch and the corresponding equations are illustred here:

The Arias intensity and the Husid duration

  """
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
     Arias Intensity 
     Defined as: pi/2g int[a(t)**2 dt]
     Defined in m/s the acceleration has to be in m/s2
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    """
    def arias(self, **kwargs):
        """
        the kwargs unit :  string g,cm/s2 or m/s2 
        since the baseline normalize the acceleration the default value is g
        """    
        unit = "g"
        for key in kwargs:
            if key == "unit":    unit = kwargs[key] 

        if   unit == "g"     :  const = (1/9.8)
        elif unit == "cm/s2" :  const = 100
        elif unit == "m/s2"  : const = 1
     
        ncoef  = np.pi/(2*9.8)
        acc = self.acc/const * np.sqrt(ncoef)
        (...)

This routine compute the Arias intensity (AI), the Husid duration (defined as time interval where the AI varies from 5% to 95% of its final value).

As for the CAV function the waveform unit is mandatory.

The routine also gives in output the evolution of AI as a function of time.

The accelerogram normalization for Arias intensity estimation

The Arias intensity is originally defined as

Arias and expressed in m/s.

To avoid any confusion with the use of constant g, I decided to go back to the original definition and to convert the acceleration in $m/s^{2}$ before applying the Arias (1970) equation.

The spectral intensities

       """
        ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
         Spectral Intensities
         Housner Instenisty defined as the integral of PSV between 0.1s and 2.5s
         Spectral Intensity defined as the integral of PSA between 0.1 and 0.5s
        ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
        """
    
    def specint (self,pst):
        """
        :param psds : pseudo spectrum (frequency, amplitude) , type numpy.array 
        :param pst : pseudospectrum type,  type boolean (psa=1 psv=0)     
        """
        if pst=="sa":
            pmin = 0.1
            pmax = 0.5
            rsp = self.sa
        elif pst=="psv":    
            pmin = 0.1
            pmax = 2.5
            rsp = self.psv
           

This function computes the spectral intensities following the original Housner definiton :

Housner

where SV is the response spectrum in velocity and the integral is performed between 0.1 s and 2.5 s. An option is also proposed to compute a SI from the integral of response spectrum in acceleration between 0.1 and 0.5 seconds.

To take into account the odd period spacing (the spectral periods are log spaced) the integral is computed as Rienmann integral.

Stockwell Transform

    def stockwell(self,data,tempo):

        """
        :param data : array of amplitude, type=np.array
        :parm tipe : array of time samples, type=np.array
        """

The Stockwell transform function requires as input the ampliutde and the time, it gives the possibility to compute it on acceleration, velocity or displacement.

The code is basically based on the code originally developped at NIMH MEG Core Facility and implemented in stockwell package.

The S-transform

The Stockwell transform (Stockwell et al. 1996) provides a time-frequency representation of the signal. The S-transform can be interpreted as an extension of the continuous wavelet transform with Gaussian windowing, as the mother wavelet with a non-null average, and dilation factor equal to the inverse of the frequency (Simon et al. 2007, Ventosa et al. 2008). The S-transform, S(t,f), is defined as:

Stockwell

where h(t) is the time history.

The integral of the S-transform along the time axis is simply the Fourier transform of the time-series h(t), and therefore S(t,f) can be interpreted as a power density spectrum unrolled along the time axis.

Warning on Stockwell Transform

The stockwell package is fast and it can be used on long time histories, however the output, given by an imaginary matrix, can be difficult to handle and to plot; in same case the plot operation leads to overflow error.

I thus suggest to not compute the Stockwell transform on uncutted signals, in the exemple reading an mseed streaming the S-transform is not computed.

Moreover, in the code the signal is undersampled to a Nyquist of 25 Hz to compute the S-transform. On the basis of my experience beyond this value the time-frequency analysis of seismic signal is not interesting because of the poor energy content (effetcs of the instrumental response, the siting and so on).

The GMPE computing

The class contains two functions computegmpe() and read_gmpeinput() based on OpenQuake hazardlib The input of the computegmpe() are listed below

   def computegmpe(self, gmpe, freq, mag, depth, ztor, dip, rake, Rx, Rrup, Rjb, Epi, vs30):  

        """
        :param gmpe : name of the GMPE on the bases of OQ GSIM list, type=str
        :param freq_gmp : frequencies, type=np.array
        :param mag : event magnitude, type=float
        :param depth : event depth, type=float
        :param ztor : ztor paramaters, type = float
        :param dip : fault dip, type=float
        :param rake : fault rake, type = float
        :param  Rx : Rx parameters, type =float
        :param Rrup : distance from the rupture, type = float 
        :param Rjb : Joyner and Boore distance, type = float
        :param Epi : epicentral distance, type = float
        :param Vs30: velocity of S waves in first 30 meters, type =float

        """

The gmpe name must be given in accordance with the OpenQuake hazardlib GSIM routine; to obtaine the list of GMPE implemented in OpenQuake

    from openquake.hazardlib import gsim, imt
       AVAILABLE_GSIMS = gsim.get_available_gsims()        
       print (AVAILABLE_GSIMS)

The second routine read_gmpeinput() organises the input parameters following the OpenQuake hazardlib GSIM routine requirements, the user do not access to this process; however, this is the routine that will be eventually updated following the GSIM developpements.

Releases

No releases published

Packages

No packages published

Languages