Welcome to the RS-EB500-Tools wiki!
- 4-55 received from R&S. USB/LSB demodulation broken. Downgraded to 4.50.
- running 4.56
- Seldom lock-ups of the receiver, generates humm, no ifpanel or iq streams. Lock-up can be ended with a short test.
- Downgraded receiver to 4.50.
- Informed R&D Customer Support, promised to send an answer after easter.
- upgraded to 4.56 again
- internal GUI lost connection to receiver, both run, but manual operation does not go through. Remote GUI still works as normal
- lock-up again, downgraded to 4.50
- again internal communication loss with error message from gui ;-(
- CAT5 cable from FP to receiver was not klicked in. Fixed.
- discovered ftp access in antenna correction factor manual, user: EB500, pwd: EB500
- also works for telnet, then some consolse commands are available, try "help"
- "rld" displays a ramlog, monitoring everything that is going on in the receiver
- what really happens when the front pannel stalls:
- the receiver still works without problems from remote
- the ramlog does not show anything special
- the front panel display follows the receiver
- input from front panel is ignored
- after some time, the input is processed
- now disassembled also the fronst panel PC, cleaned RJ45 connection with air
- since then, np more drops of eth0 in ramlog, and no more interruptions of internal gui