TBD
When run in daemon mode, argononefan
will read the temperature
of the CPU each $ARGONONEFAN_CHECK_INTERVAL
and if a threshold is crossed
set the fan speed to the according value for the current threshold.
Note
A Raspberry Pi 4 is safe to run below 85°C, according to raspberrytips.com and several other sources.
The default thresholds try to find a balance between convenience (fan off) and proper cooling (turning the fan on 100% way before a critical temperature is reached).
In the output of the help below (which is also showing the defaults), this would translate to:
Temperature | Threshold | Fan Speed |
---|---|---|
>=70°C | 70 | 100% |
61°C | 60 | 50% |
58°C | 55 | 10% |
<55°C | - | 0% (fan is off) |
With the default hysteresis of 1.0 set, if the temperature crossed a higher threshold, it must drop 1.0°C below the threshold it is coming from before the fan will be slowed down.
Say the temperature was 56°C and drops to 54.5°C. Without the hysteresis, the fan would turn off. However, with the hysteresis, the CPU would first have to cool down to 54°C or lower for the fan to stop.
Note that as a failsafe measure, the hysteresis is never applied when checking whether the fan should speed up.
$ argononefan daemon -h
Usage: argononefan daemon
Run the fan control daemon
Flags:
-h, --help Show context-sensitive help.
-d, --debug Enable debug mode ($ARGONONEFAN_DEBUG)
-f, --device-file="/sys/class/thermal/thermal_zone0/temp"
File path in sysfs containing current CPU
temperature ($ARGONONEFAN_DEVICE_FILE)
-b, --bus=0 I2C bus the fan resides on ($ARGONONEFAN_BUS)
-t, --thresholds=70=100;60=50;55=10
thresholds is map of °C to fan speed in %
($ARGONONEFAN_THRESHOLDS)
--hysteresis=1.0 hysteresis is the value in °C the temperature must
drop below a threshold before the fan is slowed
down to the according speed. This is to prevent the
fan from constantly switching between two speeds.
Note that this only applies to the fan slowing down
coming from a higher threshold, not when speeding
up.
($ARGONONEFAN_HYSTERESIS)
-i, --check-interval=5s Check interval ($ARGONONEFAN_CHECK_INTERVAL)
--prometheus-bind="localhost:8080"
Address to bind the Prometheus metrics server to
($ARGONONEFAN_PROMETHEUS_BIND)
Usage: argononefan temperature
Read the current CPU temperature
Flags:
-h, --help Show context-sensitive help.
-d, --debug Enable debug mode ($ARGONONEFAN_DEBUG)
-f, --device-file="/sys/class/thermal/thermal_zone0/temp"
File path in sysfs containing current CPU temperature
($ARGONONEFAN_DEVICE_FILE)
-b, --bus=0 I2C bus the fan resides on ($ARGONONEFAN_BUS)
-i, --imperial Display temperature in imperial system
You can set the fan speed with argononefan set-speed <speed>
.
Not that this will only temporarily overwrite the adjustments made when
argononefan
is also running in daemon mode on the same machine.
Usage: argononefan set-speed <speed>
Set the fan speed manually
Arguments:
<speed> Fan speed
Flags:
-h, --help Show context-sensitive help.
-d, --debug Enable debug mode ($ARGONONEFAN_DEBUG)
-f, --device-file="/sys/class/thermal/thermal_zone0/temp"
File path in sysfs containing current CPU temperature ($ARGONONEFAN_DEVICE_FILE)
-b, --bus=0 I2C bus the fan resides on ($ARGONONEFAN_BUS)