Expand Up @@ -21,7 +21,7 @@ elements to take into consideration:
* higher amplitudes usually correspond to better signal to noise ratio;
* at high amplitudes the signal breaks superconductivity, therefore resonator is not effectively not coupled to the qubit (we talk of bare resonator frequency);
* at intermediate amplitudes the peak could completely disappear and is, in general, not Lorentzian;
* very high amplitudes could damage the components3
* very high amplitudes could damage the components.

The bare resonator frequency can be found setting a large value for the amplitude, e.g.: