Skip to content

Commit

Permalink
feat: adds support for dry mode
Browse files Browse the repository at this point in the history
Fixes #199
  • Loading branch information
= authored and swingerman committed May 28, 2024
1 parent 4e64666 commit b65347c
Show file tree
Hide file tree
Showing 51 changed files with 2,375 additions and 382 deletions.
81 changes: 67 additions & 14 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -15,16 +15,17 @@ The `dual_smart_thermostat` is an enhanced version of generic thermostat impleme

| | | |
| :--- | :---: | :---: |
| **Heater/Cooler Mode** | <img src="docs/images/sun-snowflake.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" style="stroke: red" />](#heatcool-mode) |
| **Heater Only Mode** | <img src="docs/images/radiator.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#heater-only-mode) |
| **Two Stage (AUX) Heating Mode** | <img src="docs/images/radiator.svg" height="30" /> <img src="docs/images/plus.svg" height="30" /> <img src="docs/images/radiator.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#two-stage-heating) |
| **Fan Only mode** | <img src="docs/images/air-conditioner.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#fan-only-mode) |
| **Fan With Cooler mode** | <img src="docs/images/air-conditioner.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#fan-with-cooler-mode) |
| **Cooler Only mode** | <img src="docs/images/air-conditioner.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#cooler-only-mode) |
| **Floor Temperature Control** | <img src="docs/images/heating-coil.svg" height="30" /> <img src="docs/images/snowflake-thermometer.svg" height="30" /> <img src="docs/images/thermometer-alert.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#floor-heating-temperature-control) |
| **Window/Door sensor integration** | <img src="docs/images/window-open.svg" height="30" /> <img src="docs/images/door-open.svg" height="30" /> <img src="docs/images/chevron-right.svg" height="30" /> <img src="docs/images/timer-cog-outline.svg" height="30" /> <img src="docs/images/chevron-right.svg" height="30" /> <img src="docs/images/hvac-off.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#openings) |
| **Presets** | <img src="docs/images/sleep.svg" height="30" /> <img src="docs/images/snowflake-thermometer.svg" height="30" /> <img src="docs/images/shield-lock-outline.svg" height="30" /> | [<img src="docs/images/file-document-outline.svg" height="30" />](#presets) |
| **HVAC Action Reason** | | [<img src="docs/images/file-document-outline.svg" height="30" />](#hvac-action-reason) |
| **Heater/Cooler Mode** | ![cooler](docs/images/sun-snowflake-custom.png) | [docs](#heatcool-mode) |
| **Heater Only Mode** | ![heating](/docs/images/fire-custom.png) | [docs](#heater-only-mode) |
| **Two Stage (AUX) Heating Mode** | ![heating](/docs/images/fire-custom.png) ![heating](/docs/images/radiator-custom.png) | [docs](#two-stage-heating) |
| **Fan Only mode** | ![fan](/docs/images/fan-custom.png) | [docs](#fan-only-mode) |
| **Fan With Cooler mode** | ![fan](/docs/images/fan-custom.png) ![cool](/docs/images/snowflake-custom.png) | [docs](#fan-with-cooler-mode) |
| **Cooler Only mode** | ![cool](/docs/images/snowflake-custom.png) | [docs](#cooler-only-mode) |
| **Dry mode** | ![humidity](docs/images/water-percent-custom.png) | [docs](#dry-mode) |
| **Floor Temperature Control** | ![heating-coil](docs/images/heating-coil-custom.png) ![snowflake-thermometer](docs/images/snowflake-thermometer-custom.png) ![thermometer-alert](docs/images/thermometer-alert-custom.png) | [docs](#floor-heating-temperature-control) |
| **Window/Door sensor integration** | ![window-open](docs/images/window-open-custom.png) ![window-open](docs/images/door-open-custom.png) ![chevron-right](docs/images/chevron-right-custom.png) ![timer-cog](docs/images/timer-cog-outline-custom.png) ![chevron-right](docs/images/chevron-right-custom.png) ![hvac-off](docs/images/hvac-off-custom.png)| [docs](#openings) |
| **Presets** | | [docs](#presets) |
| **HVAC Action Reason** | | [docs](#hvac-action-reason) |

## Heat/Cool Mode

Expand Down Expand Up @@ -111,7 +112,6 @@ This feature let's you do just that.
In order to use this feature you need to set the [`heater`](#heater) entity, the [`ac_mode`](#ac_mode), the [`fan)`](#fan) entity and the [`fan_on_with_ac`](#fan_on_with_ac) to `true`.



### example
```yaml
heater: switch.study_heater
Expand All @@ -126,6 +126,35 @@ If only the [`cooler`](#cooler) entity is set the thermostat works only in cooli

[all features ⤴️](#features)

## Dry mode

If the [`dryer`](#dryer) entity is set the thermostat can switch to dry mode. The dryer will turn on when the humidity is above the target humidity and the [`moist_tolerance`](#moist_tolerance) is not reached. If the humidity is above the target humidity and the [`moist_tolerance`](#moist_tolerance) is reached the dryer will stop.


### Dry Mode Example with cooler

```yaml
heater: switch.study_heater
target_sensor: sensor.study_temperature
ac_mode: true
dryer: switch.study_dryer
humidity_sensor: sensor.study_humidity
moist_tolerance: 5
dry_tolerance: 5
```

### Dryer example in dual mode

```yaml
heater: switch.study_heater
cooler: switch.study_cooler
target_sensor: sensor.study_temperature
dryer: switch.study_dryer
humidity_sensor: sensor.study_humidity
moist_tolerance: 5
dry_tolerance: 5
```

## Openings

The `dual_smart_thermostat` can turn off heating or cooling if a window or door is opened and turn heating or cooling back on when the door or window is closed to save energy.
Expand All @@ -143,7 +172,7 @@ The `openings_scope` configuration variable defines the scope of the openings. I
### Openings Scope Configuration

```yaml
openings_scope: [heat, cool, heat_cool, fan_only]
openings_scope: [heat, cool, heat_cool, fan_only, dry]
```

```yaml
Expand Down Expand Up @@ -248,11 +277,14 @@ The internal values can be set by the component only and the external values can
| `target_temp_not_reached` | The target temperature has not been reached |
| `target_temp_not_reached_with_fan` | The target temperature has not been reached trying it with a fan |
| `target_temp_reached` | The target temperature has been reached |
| `target_humidity_reached` | The target humidity has been reached |
| `target_humidity_not_reached` | The target humidity has not been reached |
| `misconfiguration` | The thermostat is misconfigured |
| `opening` | The thermostat is idle because an opening is open |
| `limit` | The thermostat is idle because the floor temperature is at the limit |
| `overheat` | The thermostat is idle because the floor temperature is too high |
| `TEMPERATURE_SENSOR_TIMED_OUT` | The thermostat is idle because the temperature sensor is not provided data for the defined time that could indicate a malfunctioning sensor |
| `temperature_sensor_stalled` | The thermostat is idle because the temperature sensor is not provided data for the defined time that could indicate a malfunctioning sensor |
| `humidity_sensor_sstalled` | The thermostat is idle because the temperature sensor is not provided data for the defined time that could indicate a malfunctioning sensor |

#### HVAC Action Reason External values

Expand Down Expand Up @@ -337,11 +369,32 @@ The internal values can be set by the component only and the external values can

_requires: `fan` , `sensor_outside`_


### dryer

_(optional) (string)_ "`entity_id` for dryer switch, must be a toggle device."

### moist_tolerance

_(optional) (float)_ Set a minimum amount of difference between the humidity read by the sensor specified in the _humidity_sensor_ option and the target humidity that must change prior to being switched on. For example, if the target humidity is 50 and the tolerance is 5 the dryer will start when the sensor equals or goes below 45.

_requires: `dryer`, `humidity_sensor`_

### dry_tolerance

_(optional) (float)_ Set a minimum amount of difference between the humidity read by the sensor specified in the _humidity_sensor_ option and the target humidity that must change prior to being switched off. For example, if the target humidity is 50 and the tolerance is 5 the dryer will stop when the sensor equals or goes above 55.

_requires: `dryer`, `humidity_sensor`_

### humidity_sensor

_(optional) (string)_ "`entity_id` for a humidity sensor, humidity_sensor.state must be humidity."

### target_sensor

_(required) (string)_ "`entity_id` for a temperature sensor, target_sensor.state must be temperature."

### target_sensor_safety_delay
### sensor_stale_duration

_(optional) (timedelta)_ Set a delay for the target sensor to be considered valid. If the sensor is not available for the specified time the thermostat will be turned off.

Expand Down
2 changes: 1 addition & 1 deletion config/configuration.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -366,7 +366,7 @@ climate:
humidity_sensor: sensor.humidity
heat_cool_mode: true
target_temp_step: 0.1
target_sensor_safety_delay: "00:10"
sensor_stale_duration: "00:10"
precision: 0.1
min_temp: 9
max_temp: 32
Expand Down
Loading