Skip to content

v0.9.1

Compare
Choose a tag to compare
@swingerman swingerman released this 11 Aug 21:04
· 142 commits to master since this release

What's Changed

openings:
  - sensor.window1
  - sensor.window2
  - entity_id: binary_sensor.window3
    timeout: 00:00:30 # cosnidered to be open if still open after 30 seconds
  • Tolerances

The dual_smart_thermostat has two tolerance variables: cold_tolerance and hot_tolerance. These variables are used to prevent the heater or cooler from switching on and off too frequently. For example, if the target temperature is 25 and the tolerance is 0.5 the heater will start when the sensor equals or goes below 24.5. The heater will stop when the sensor equals or goes above 25.5. This prevents the heater from switching on and off too frequently when the temperature is close to the target temperature.

If the thermosat is set to heat_cool mode the tolerance will work in the same way for both the heater and the cooler.

climate:
  - platform: dual_smart_thermostat
    name: Study
    heater: switch.study_heater
    cooler: switch.study_cooler
    target_sensor: sensor.study_temperature
    cold_tolerance: 0.3
    hot_tolerance: 0

Full Changelog: v0.9.0...v0.9.1