12 changes: 12 additions & 0 deletions src/backend/columnar/columnar_tableam.c
Original file line number Diff line number Diff line change
Expand Up @@ -1437,7 +1437,19 @@ columnar_scan_analyze_next_block(TableScanDesc scan,
* to pages boundaries. So not much to do here. We return true anyway
* so acquire_sample_rows() in analyze.c would call our
* columnar_scan_analyze_next_tuple() callback.
* In PG17, we return false in case there is no buffer left, since
* the outer loop changed in acquire_sample_rows(), and it is
* expected for the scan_analyze_next_block function to check whether
* there are any blocks left in the block sampler.
*/
#if PG_VERSION_NUM >= PG_VERSION_17
Buffer buf = read_stream_next_buffer(stream, NULL);
if (!BufferIsValid(buf))
{
return false;
}
ReleaseBuffer(buf);
#endif
return true;
}

Expand Down