The following attempts to be a list of Insteon devices which are known to work with MisterHouse.
Note it is simply not possible to keep this table complete and up-to-date. Devices similar to the ones listed below likely work as well. If in doubt, before purchasing a specific product please see the DiscussionForums. Generally, you can use the SwitchLinc definition and class to enable basic on/off functionality for a new device.
Name | Model # | Support | Definition | Documentation |
---|---|---|---|---|
PLM - PowerLinc Modem |
2412S 2412U 2412UH 2413S (Dual-Band) 2413U (Dual-Band) |
Yes | INSTEON_PLM | InsteonPLM |
Insteon Hub | 2242-222 | Yes | INSTEON_PLM | InsteonPLM |
Portable USB Adapter | 2448A7 | Yes | INSTEON_PLM | InsteonPLM InsteonRFOnly |
PLC - PowerLinc Controller |
2414S 2414U |
No | Will never be supported. | |
ControlLinc | 2430 | No |
Old device. Likely will never see support (see this post) |
|
RemoteLinc | 2440 | Yes | INSTEON_REMOTELINC | RemoteLinc Class InsteonRFOnly |
IOLinc | 2450 | Yes | INSTEON_IOLINC | IO_Linc Class |
EZIO | EZIOxXx | Limited | Maybe with INSTEON_IOLINC | See IO_Linc Class |
LampLinc |
2456D3 2456D2 2856D2 |
Yes | INSTEON_LAMPLINC | LampLinc Class |
BulbLinc aka Insteon LED Bulb aka Insteon LED Bulb for Recessed Lights, Floodlights |
2672-222 (9W) 2674-222 (12W) |
Yes | INSTEON_BULBLINC | BulbLinc Class |
ApplianceLinc | 2456S3 | Yes | INSTEON_APPLIANCELINC | ApplianceLinc Class |
SwitchLinc ToggleLinc |
2476DH 2477DH (Dual-Band) 2876D 2466D |
Yes | INSTEON_SWITCHLINC | SwitchLinc Class |
SwitchLinc Relay ToggleLinc Relay |
2476D 2477D (Dual-Band) 2466S |
Yes | INSTEON_SWITCHLINCRELAY | SwitchLincRelay Class |
In-LineLinc | 2475D | Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class |
OutletLinc |
2472D (Dual-Band) 2473D |
Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class |
OutletLinc Relay | 2473S | Yes | Use INSTEON_SWITCHLINCRELAY | SwitchLincRelay Class |
SocketLinc | 2454D | Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class |
KeypadLinc |
2486D 2334 (Dual-Band) |
Yes | INSTEON_KEYPADLINC | KeyPadLinc Class |
KeypadLinc Relay |
2486S 2487S (Dual-Band) |
Yes | INSTEON_KEYPADLINCRELAY | KeyPadLincRelay Class |
Motion Sensor aka MotionLinc |
2842-222 2420M (deprecated) |
Yes | INSTEON_MOTIONSENSOR | MotionSensor Class InsteonRFOnly |
Thermostat | 2441TH | Yes | INSTEON_THERMOSTAT |
Insteon_Thermostat Class Note: Not a 'deaf' Device InsteonRFOnly |
EZFlora aka EZRain |
EZFloraIV1 | Yes | INSTEON_IRRIGATION | Insteon_Irrigation Class |
TriggerLinc |
2843-222 2421 (deprecated) |
Yes | INSTEON_TRIGGERLINC | Insteon_TriggerLinc Class InsteonRFOnly |
FanLinc | 2475F | Yes | INSTEON_FANLINC | Insteon_FanLinc Class |
MicroSwitch |
2442-222 (Dimmer) 2443-222 (On/Off) 2444-222 (Open/Close) |
Yes | INSTEON_MICROSWITCH | MicroLinc Class |
SynchroLinc | 2423A5 | Yes | INSTEON_SYNCHROLINC | Insteon_SynchroLinc Class |
iMeter | 2423A1 | Yes | INSTEON_IMETER | Insteon_iMeter Class |